Pharmacotherapy The Journal of Human Pharmacology and Drug Therapy · 2022 · 16 citations · 27 references
MedicineClinical SciencesNephrologyCritical Care MedicineRenal PharmacokineticsRenal Replacement TherapyIntensive Care MedicinePharmacokinetics In Critical IllnessRenal ClearanceRenal DiseaseRenal Function TestsRenal ImpairmentCreatinine Clearance ComparisonCreatinine Clearance FormulasCreatinine Clearance ModelingCreatinine Clearance MonitoringEstimated Creatinine ClearanceObjective Evaluation
Abstract Study objective The primary objective was to evaluate the performance of the Cockcroft‐Gault (CG) equation with different body weights (BWs) compared to a measured creatinine clearance (mCrCl) in an intensive care unit (ICU) population with and without augmented renal clearance (ARC). Design Multicenter, retrospective cohort. Setting Two ICUs in the United States and four ICUs from a previous international observational analysis. Patients Adult ICU patients admitted from January 1, 2010 to July 30, 2020 with at least one mCrCl collected within the initial 10 days of hospitalization were eligible for inclusion. Measurements and main results The primary outcome was the performance of the CG equation in ARC (mCrCl≥130 ml/min/1.73 m 2 ) and non‐ARC (mCrCl<130 ml/min/1.73 m 2 ) patients. Correlation was analyzed by Pearson's correlation coefficient, bias by mean difference, and accuracy by the percentage of patients within 30% of the mCrCl. A total of 383 patients were included, which provided 1708 mCrCl values. The majority were male ( n = 239, 62%), median age of 55 years [IQR 40–65] with a surgical diagnosis ( n = 239, 77%). ARC was identified in 229 (60%) patients. The ARC group had lower Scr values (0.6 [0.5–0.7] vs. 0.7 [0.6–0.9] mg/dl, p < 0.001) and higher mCrCl (172.8 (SD 39.1) vs. 89.9 mL/min/1.73 m 2 (SD 25.4), p < 0.001) compared with the non‐ARC group, respectively. Among non‐ARC patients there was a moderate correlation ( r = 0.33–0.39), moderate accuracy (range 48–58%), and low bias (range of −12.9 to 17.1) among the different BW estimations with the adjusted BW having the better performance. Among ARC patients there was low correlation ( r = 0.24–0.28), low to moderate accuracy (range 38–70%), and high bias (range of −58.5 to −21.6). Conclusions The CG‐adjusted BW had the best performance in the non‐ARC patients, while CG performed poorly with any BW in ARC patients. Although the CG equation remains the standard equation for estimating CrCl in the ICU setting, a new, validated equation is needed for patients with ARC.
27
Paul A. Harris, Robert Taylor, Robert J. Thielke et al. · Journal of Biomedical Informatics · 2008 · 51.7K citations · Full text
Quantification of Lean Bodyweight
Sarayut Janmahasatian, Stephen B. Duffull, Susan Ash et al. · Clinical Pharmacokinetics · 2005 · 896 citations
Augmented Renal Clearance in the ICU
Andrew Udy, João Pedro Baptista, Noelle Lim et al. · Critical Care Medicine · 2013 · 275 citations