PLoS ONE · 2022 · 14 citations · 44 references
MedicineAnatomySports MedicineOrthopedicsUltrasonographyUltrasoundMuscle StructureMuscular AnatomyMusculoskeletal AnatomyMusculoskeletal UltrasonographyMusculoskeletal UltrasoundFascicle LengthMuscle ArchitectureMuscle Fascicle ArchitectureMuscle Fascicle LengthMuscle Length AssessmentMuscle ThicknessPennation AngleUltrasound-based Muscle Assessment
PURPOSE: To assess the intra-rater reliability of static wide field of view ultrasound to quantify the architectural characteristics of the hamstring muscles. METHODS: Twenty amateur male athletes were recruited. Their left hamstring muscles were assessed using static wide field of view ultrasound on two separate occasions. Static ultrasound images were acquired by a single sonographer using a 92mm linear transducer. The architectural characteristics (muscle length, fascicle length, pennation angle and muscle thickness) from two distinct locations of the bicep femoris long head and semimembranosus were evaluated. Muscle length and thickness of the bicep femoris short head and semitendinosus muscle were also evaluated. Intraclass correlation coefficient analyses were performed to determine the intra-rater reliability of the performed measurements. RESULTS: Both muscle (intraclass correlation coefficient = 0.99; standard error of measurement = 4.3 to 6.6mm) and fascicle (intraclass correlation coefficient = 0.92 to 0.98; standard error measurement = 1.1 to 2.4mm) length were measured with excellent intra-rater reliability. Muscle thickness was measured with excellent reliability (intraclass correlation coefficient = 0.9 to 0.96; standard error of measurement = 0.91mm to 1.4mm) for all hamstring muscles except for the proximal segments of the bicep femoris short head (intraclass correlation coefficient = 0.85; standard error of measurement = 0.84mm) and semitendinosus (intraclass correlation coefficient = 0.88; standard error of measurement = 0.82mm), which were measured with good reliability. Pennation angle was measured with good reliability (intraclass correlation coefficient = 0.77 to 0.87; standard error of measurement = 1 to 1.6°). CONCLUSION: The architectural characteristics of the hamstring muscles of male amateur athletes can be reliably quantified using static wide field of view ultrasound.
44
Measures of Reliability in Sports Medicine and Science
Will G. Hopkins · Sports Medicine · 2000 · 4.5K citations
Muscle Architecture of the Human Lower Limb
Thomas L. Wickiewicz, Roland R. Roy, P. L. Powell et al. · Clinical Orthopaedics and Related Research · 1983 · 928 citations
Medicine, Anatomy, Physiology +17
Jan Ekstrand, Markus Waldén, Martin Hägglund · British Journal of Sports Medicine · 2016 · 692 citations · Full text
Are Current Measurements of Lower Extremity Muscle Architecture Accurate?
Samuel R. Ward, Carolyn M. Eng, Laura Smallwood et al. · Clinical Orthopaedics and Related Research · 2008 · 690 citations · Full text
Medicine, Anatomy, Physiology +17