IEEE Transactions on Biomedical Circuits and Systems · 2022 · 22 citations · 33 references
EngineeringBiomedical EngineeringElectrical EngineeringBioinstrumentationBiomedical Signal ProcessingPower ElectronicsModulationWireless Power TransferBiomedical Wireless Power TransferCoil DesignDemodulationFull-wave RectifiersInductive Power TransferLoadPower ConversionTelemetry Modulation Schemes
This paper presents a hybrid load-shift keying (LSK) modulation for a load-insensitive back telemetry system to realize near-constant voltage changes in a primary coil ( <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">L<sub>1</sub></i> ) against a wide range of load variations. The hybrid-LSK-enabled full-wave rectifier enables the sequential combination of open- and short-coil functions for hybrid-LSK modulation in addition to wireless power conversion operation. Load-insensitive <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">L<sub>1</sub></i> voltage changes can be demodulated using the proposed slope- based demodulator, which utilizes the threshold slope of <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">L<sub>1</sub></i> voltage changes over the back data pulse width, enabling robust data recovery regardless of the load conditions. The 0.56-mm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sup> 0.18-μm standard CMOS hybrid-LSK prototype demonstrated that the variation of <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">L<sub>1</sub></i> voltage changes could be minimized to 60 mV under load changes between 50 Ω and 50 kΩ at coil separation distance of 10 mm, achieving 88.2% reduction compared to the conventional short-coil LSK with 510 mV variation. The proposed back telemetry system also achieved a bit error rate (BER) of < 9.1 × 10 <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">−10</sup> under load ranges from 50 Ω to 50 kΩ and data rate of 1 Mbps, ensuring reliable back data recovery against load variations.
33
Design and analysis of an adaptive transcutaneous power telemetry for biomedical implants
Guoxing Wang, Wentai Liu, Mohanasankar Sivaprakasam et al. · IEEE Transactions on Circuits and Systems I Fundamental Theory and Applications · 2005 · 433 citations
Engineering, Biomedical Engineering, Electrical Engineering +16
A Minimally Invasive 64-Channel Wireless μECoG Implant
Rikky Muller, Hanh‐Phuc Le, Wen Li et al. · IEEE Journal of Solid-State Circuits · 2014 · 368 citations · Full text
Engineering, Biomedical Engineering, Electrical Engineering +17
Deep brain optogenetics without intracranial surgery
Ritchie Chen, Felicity Gore, Quynh-Anh Nguyen et al. · Nature Biotechnology · 2020 · 238 citations · Full text