IEEE Transactions on Magnetics · 2021 · 24 citations · 36 references
EngineeringElectrical EngineeringMaterials ScienceOpticsPhotonicsSensorsOptical SensingOptical WaveguidesPlasmonic MaterialsPlasmonicsSpintronic MaterialsSpintronicsHall EffectMagnetic Field EffectsMagneto-optical PropertiesPlasmonic SensingSensor TechnologySilicon WaveguidesSpin Hall EffectSpin-dependent Optical Properties
In this work, we propose and analyze a plasmonic sensor with a three-layer waveguide structure. We consider the transverse spin-dependent shift (SDS) of the horizontal photonic spin Hall effect (PSHE) in the waveguide at a given wavelength (1557 nm) for a TM (transverse magnetic or p-polarized) mode. The sensor structure is analyzed in two ways. First, under the normal methods, that is, angular and intensity interrogation methods, for which the results indicate that the maximum figure of merit (FOM) of 4007.0 RIU <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">−1</sup> is attained for an optimum thickness ( <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$d_{2}=51$ </tex-math></inline-formula> nm) of the gold layer and this FOM is significantly greater than the corresponding FOM (413.7 RIU <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">−1</sup> ) reported earlier (for a 50 nm thick gold layer). Also, the average sensitivity increases from 0.0005 to 0.002°/Oe when the volume fraction of Fe <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sub> O <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">4</sub> particles ( <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$c$ </tex-math></inline-formula> ) in the magnetic fluid is increased from 1.48% to 1.93%. Correspondingly, a considerably finer value of the resolution (0.046 Oe) is obtained when the volume fraction is increased to 1.93% (compared to 0.199 Oe at 1.48%). Second way is the proposed method of PSHE, for which the analysis indicates that transverse SDS of the horizontal PSHE is the maximum for <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$d_{2} = 51$ </tex-math></inline-formula> nm leads to the maximum sensitivity <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$6.25 \times 10^{7}~\mu$ </tex-math></inline-formula> m/RIU for an amplified angle <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\Delta = 0.1^{\circ}$ </tex-math></inline-formula> and <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$1.09 \times 10^{6}~\mu$ </tex-math></inline-formula> m/RIU for <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\Delta = 0.1$ </tex-math></inline-formula> rad in the conventional weak measurements. The corresponding finest possible resolution of magnetic field detection at 1.93% is <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$1.5 \times 10^{-6}$ </tex-math></inline-formula> Oe in the conventional weak measurements for <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\Delta = 0.1^{\circ}$ </tex-math></inline-formula> and <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$7.8 \times 10^{-8}$ </tex-math></inline-formula> Oe in the modified weak measurements for <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\Delta = 0.5$ </tex-math></inline-formula> rad, which are significantly finer than those existing in the related state of the art. The above resolution is also superior to those found under normal methods mentioned earlier. Furthermore, the effect of temperature (24.3 °C–60 °C) on PSHE-based magnetic field sensor’s performance is also analyzed which indicates that the proposed PSHE-based magnetic field sensor should be operated in a thermally controlled milieu.
36
Nicolò Maccaferri, Keith Gregorczyk, Thales V. A. G. de Oliveira et al. · Nature Communications · 2015 · 221 citations · Full text
Temperature-dependent optical properties of gold thin films
Harsha Reddy, Urcan Guler, Alexander V. Kildishev et al. · Optical Materials Express · 2016 · 188 citations · Full text