Physica Medica · 2021 · 12 citations · 19 references
MedicineNuclear MedicineRadiologyDiagnostic ImagingDiagnostic RadiologyRadiation DosimetryComputed TomographyIn Vivo DosimetryMedical ImagingMonte Carlo DosimetryPatient-specific DosimetryTreatment Planning Dose CalculationComputed Tomography Phantom DosimetryCt Image ReconstructionGamma Camera ImagingGamma Camera SystemsImage-based Dose CalculationImaging-based DosimetryPatient-specific Dose CalculationTherapeutic Dosimetry
PURPOSE: Patient-specific dosimetry in MRT relies on quantitative imaging, pharmacokinetic assessment and absorbed dose calculation. The DosiTest project was initiated to evaluate the uncertainties associated with each step of the clinical dosimetry workflow through a virtual multicentric clinical trial. This work presents the generation of simulated clinical SPECT datasets based on GATE Monte Carlo modelling with its corresponding experimental CT image, which can subsequently be processed by commercial image workstations. METHODS: Lu-labelled DOTATATE derived from an IAEA-Coordinated Research Project (E23005) on "Dosimetry in Radiopharmaceutical therapy for personalised patient treatment". Patient images were acquired on a GE Infinia-Hawkeye 4 gamma camera using a medium energy (ME) collimator. Simulated SPECT projections were generated based on experimental time points and validated against experimental SPECT projections using flattened profiles and gamma index. The simulated projections were then incorporated into the patient SPECT/CT DICOM envelopes for processing and their reconstruction within a commercial image workstation. RESULTS: Gamma index passing rate (2% - 1 pixel criteria) between 95 and 98% and average gamma between 0.28 and 0.35 among different time points revealed high similarity between simulated and experimental images. Image reconstruction of the simulated projections was successful on HERMES and Xeleris workstations, a major step forward for the initiation of a multicentric virtual clinical dosimetry trial based on simulated SPECT/CT images. CONCLUSIONS: Lu patient SPECT projections were generated in GATE. These modelled datasets will be circulated to different clinical departments to perform dosimetry in order to assess the uncertainties in the entire dosimetric chain.
19
3D Slicer as an image computing platform for the Quantitative Imaging Network
Andriy Fedorov, Reinhard Beichel, Jayashree Kalpathy–Cramer et al. · Magnetic Resonance Imaging · 2012 · 8.9K citations · Full text
Arts, Computer Science, Radiology +12
GATE: a simulation toolkit for PET and SPECT
S Jan, G. Santin, D. Strul et al. · Physics in Medicine and Biology · 2004 · 2.1K citations · Full text
Michael Ljungberg, A. Ćeller, Mark Konijnenberg et al. · Journal of Nuclear Medicine · 2015 · 350 citations · Full text
From medical imaging data to 3D printed anatomical models
Thore Mainart Bücking, Emma R. Hill, J. L. Robertson et al. · PLoS ONE · 2017 · 270 citations · Full text
SlicerRT: Radiation therapy research toolkit for 3D Slicer
Csaba Pintér, András Lassó, An Wang et al. · Medical Physics · 2012 · 268 citations