JTCVS Open · 2021 · 30 citations · 34 references
Life SciencesCardiologyImmunologyImmunoregulationImmunotherapyInflammationAntibody CharacterizationAntibody FunctionAntibody-mediated RejectionImmunoglobulin FunctionImmunostimulatory TherapyImplantation ImmunologyBioprosthetic Heart ValvesDurability Of Bioprosthetic ValvesImmune Response AssessmentImmune Response RegulationImmune Response To Cardiac ImplantsInflammatory Mediator ResponseMitraclip TherapySystemic Inflammation Markers
Objective: Transcatheter aortic valve implantation (TAVI) is rapidly replacing cardiac surgery due to its minimal invasiveness and practicality. Midterm immunological studies on the biocompatibility of galactose-alpha-1,3-galactose (α-Gal)-carrying bioprosthetic heart valves for TAVI are not available. In this study we investigated whether bioprosthetic heart valves employed for TAVI augment an α-Gal-specific antibody-dependent and antibody-independent immune response 3 months after TAVI implantation. Methods: This prospective observational study included 27 patients with severe aortic valve stenosis undergoing TAVI and 10 patients with severe mitral valve regurgitation treated with a transcatheter MitraClip (Abbott Laboratories, Abbott Park, Ill) procedure. Blood samples were drawn before and 90 days after treatment at a routine checkup. Serum samples were analyzed using enzyme-linked immunosorbent assay. Serum concentrations of α-Gal-specific immunoglobulin (Ig) G, IgG subclasses and IgE, complement factor 3a, NETosis-specific citrullinated H3, and the systemic inflammation markers soluble suppression of tumorigenicity and interleukin 33 were evaluated. Results: = .039, respectively). Sensitization of α-Gal-specific IgE antibodies occurred in 55% of all patients after TAVI. Conclusions: Our results indicate that TAVI elicits a midterm, specific humoral immune response against α-Gal and causes an unspecific humoral inflammation compared with patients undergoing MitraClip implantation. This observation will lead to a better understanding of postintervention morbidity and the long-term durability of bioprostheses and indicates that caution is appropriate when designing implantation strategies for younger patients.
34
2017 ESC/EACTS Guidelines for the management of valvular heart disease
Helmut Baumgartner, Volkmar Falk, Jeroen J. Bax et al. · European Heart Journal · 2017 · 6.3K citations · Full text
Medicine, Cardiology, Surgery +14
Karl E. Hammermeister, Gulshan K. Sethi, William G. Henderson et al. · Journal of the American College of Cardiology · 2000 · 1.1K citations
Scott P. Commins, Shama M. Satinover, Jacob D. Hosen et al. · Journal of Allergy and Clinical Immunology · 2008 · 679 citations