Review of Scientific Instruments · 2021 · 14 citations · 22 references
EngineeringMechanical EngineeringMechanical DesignStructural DynamicsVibrationLateral VibrationMulti-degree-of-freedom SystemsSpring DesignStructural VibrationVibration ControlVibration IsolationAnalytical ModelsIsolator DesignLateral Vibration IsolationResonanceStructural Vibration IsolationVibration DesignVibration Isolation DesignVibration Isolator Design
A novel design allows column springs in Euler buckling mode to be laterally stable and thus provides vibration isolation in six degrees of freedom. Analytical models of the stiffness were used to develop a design with a vertical resonance of 1.13 Hz, a horizontal resonance of 1.68 Hz, and a roll resonance of 2.58 Hz. A prototype vibration isolator reduces vertical vibration by a factor of 2 at 2 Hz. Vertical, horizontal, and roll vibrations are reduced by a factor of 100 at frequencies above 20 Hz.
22
Recent advances in nonlinear passive vibration isolators
R. A. Ibrahim · Journal of Sound and Vibration · 2008 · 1.2K citations