MedicineCardiologySurgeryBiomedical ImagingCardiothoracic SurgeryDiagnostic ImagingCardiac Valve SurgeryMitral Valve DiseaseComputer-aided Surgical SimulationDecision Support System ModelsHeart Valve ModelingInteractive Geometry EditingMitral Valve AnatomyPosition-based DynamicsSurgical SimulationValves
PURPOSE: Decision support systems for mitral valve disease are an important step toward personalized surgery planning. A simulation of the mitral valve apparatus is required for decision support. Building a model of the chordae tendineae is an essential component of a mitral valve simulation. Due to image quality and artifacts, the chordae tendineae cannot be reliably detected in medical imaging. METHODS: Using the position-based dynamics framework, we are able to realistically simulate the opening and closing of the mitral valve. Here, we present a heuristic method for building an initial chordae model needed for a successful simulation. In addition to the heuristic, we present an interactive editor to refine the chordae model and to further improve pathology reproduction as well as geometric approximation of the closed valve. RESULTS: For evaluation, five mitral valves were reconstructed based on image sequences of patients scheduled for mitral valve surgery. We evaluated the approximation of the closed valves using either just the heuristic chordae model or a manually refined model. Using the manually refined models, prolapse was correctly reproduced in four of the five cases compared to two of the five cases when using the heuristic. In addition, using the editor improved the approximation in four cases. CONCLUSIONS: Our approach is suitable to create realistically parameterized mitral valve apparatus reconstructions for the simulation of normally and abnormally closing valves in a decision support system.
10
Felix Ritter, Tobias Boskamp, André Homeyer et al. · IEEE Pulse · 2011 · 375 citations
Miles Macklin, Matthias Müller, Nuttapong Chentanez · 2016 · 302 citations
Engineering, Computational Engineering, Computational Mechanics +13
On modelling and analysis of healthy and pathological human mitral valves: Two case studies
Victorien Prot, Bjørn Skallerud, Gerhard Sommer et al. · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · 2009 · 121 citations
Medicine, Cardiology, Physiology +13
Tommaso Mansi, Ingmar Voigt, Bogdan Georgescu et al. · Medical Image Analysis · 2012 · 104 citations