Clinical Chemistry · 2020 · 243 citations · 31 references
MedicineInfectious DiseasesMicrobiologyMolecular DiagnosticsMolecular VirologyVirologyInfectious Disease Molecular TestingNucleic Acid Amplification TestingPathogen DetectionViral DiagnosticsDiagnostic TestingLoop-mediated Isothermal AmplificationLoop-mediated Isothermal Amplification (Lamp)Polymerase Chain Reaction DetectionRna ExtractionSalivary Infectious Disease TestingSalivary Nucleic Acid DetectionSalivary Virology
BACKGROUND: Rapid, reliable, and widespread testing is required to curtail the ongoing COVID-19 pandemic. Current gold-standard nucleic acid tests are hampered by supply shortages in critical reagents including nasal swabs, RNA extraction kits, personal protective equipment, instrumentation, and labor. METHODS: To overcome these challenges, we developed a rapid colorimetric assay using reverse-transcription loop-mediated isothermal amplification (RT-LAMP) optimized on human saliva samples without an RNA purification step. We describe the optimization of saliva pretreatment protocols to enable analytically sensitive viral detection by RT-LAMP. We optimized the RT-LAMP reaction conditions and implemented high-throughput unbiased methods for assay interpretation. We tested whether saliva pretreatment could also enable viral detection by conventional reverse-transcription quantitative polymerase chain reaction (RT-qPCR). Finally, we validated these assays on clinical samples. RESULTS: The optimized saliva pretreatment protocol enabled analytically sensitive extraction-free detection of SARS-CoV-2 from saliva by colorimetric RT-LAMP or RT-qPCR. In simulated samples, the optimized RT-LAMP assay had a limit of detection of 59 (95% confidence interval: 44-104) particle copies per reaction. We highlighted the flexibility of LAMP assay implementation using 3 readouts: naked-eye colorimetry, spectrophotometry, and real-time fluorescence. In a set of 30 clinical saliva samples, colorimetric RT-LAMP and RT-qPCR assays performed directly on pretreated saliva samples without RNA extraction had accuracies greater than 90%. CONCLUSIONS: Rapid and extraction-free detection of SARS-CoV-2 from saliva by colorimetric RT-LAMP is a simple, sensitive, and cost-effective approach with broad potential to expand diagnostic testing for the virus causing COVID-19.
31
Loop-mediated isothermal amplification of DNA
Tsugunori Notomi · Nucleic Acids Research · 2000 · 8.8K citations · Full text
Detection of SARS-CoV-2 in Different Types of Clinical Specimens
Yanli Xu, Ruqin Gao, Roujian Lu et al. · JAMA · 2020 · 5.3K citations · Full text
Temporal dynamics in viral shedding and transmissibility of COVID-19
Xi He, Eric H. Y. Lau, Peng Wu et al. · Nature Medicine · 2020 · 4.7K citations · Full text
Veterinary Medicine, Infectious Disease Control, Infectious Diseases +17