IUCrJ · 2020 · 158 citations · 22 references
Natural SciencesCell BiologyBiomedical ImagingComputer VisionDigital ImagingCryo-electron MicroscopyDigital Image ProcessingElectron CountingElectron MicroscopyImage ProcessingVideo RecordingCryo-electron Microscopy Data AnalysisCryogenic Electron MicroscopyCryogenic Transmission Electron MicroscopyDetective Quantum EfficiencyQuantum EfficiencySuper-resolutionSuper-resolution ImagingTemporal Super-resolution
Direct detector device (DDD) cameras have revolutionized electron cryomicroscopy (cryoEM) with their high detective quantum efficiency (DQE) and output of movie data. A high ratio of camera frame rate (frames per second) to camera exposure rate (electrons per pixel per second) allows electron counting, which further improves the DQE and enables the recording of super-resolution information. Movie output also allows the correction of specimen movement and compensation for radiation damage. However, these movies come at the cost of producing large volumes of data. It is common practice to sum groups of successive camera frames to reduce the final frame rate, and therefore the file size, to one suitable for storage and image processing. This reduction in the temporal resolution of the camera requires decisions to be made during data acquisition that may result in the loss of information that could have been advantageous during image analysis. Here, experimental analysis of a new electron-event representation (EER) data format for electron-counting DDD movies is presented, which is enabled by new hardware developed by Thermo Fisher Scientific for their Falcon DDD cameras. This format enables the recording of DDD movies at the raw camera frame rate without sacrificing either spatial or temporal resolution. Experimental data demonstrate that the method retains super-resolution information and allows the correction of specimen movement at the physical frame rate of the camera while maintaining manageable file sizes. The EER format will enable the development of new methods that can utilize the full spatial and temporal resolution of DDD cameras.
22
A Mathematical Theory of Communication
Claude E. Shannon · Bell System Technical Journal · 1948 · 80.7K citations
cryoSPARC: algorithms for rapid unsupervised cryo-EM structure determination
Ali Punjani, John L. Rubinstein, David J. Fleet et al. · Nature Methods · 2017 · 10.7K citations
MotionCor2: anisotropic correction of beam-induced motion for improved cryo-electron microscopy
Shawn Zheng, Eugene Palovcak, Jean‐Paul Armache et al. · Nature Methods · 2017 · 8.9K citations · Full text