Analytical Chemistry · 2020 · 357 citations · 16 references
Life SciencesDiagnostic SciencesInfectious DiseasesMolecular DiagnosticsMolecular VirologyVirologyDiagnostic DevelopmentInfectious Disease Molecular TestingPoint-of-care Diagnostic DevicesPolymerase Chain ReactionRapid Diagnostic TestsSerological DiagnosticsCoronavirus DiagnosticsDiagnostic Assay DevelopmentDiagnostic TestingLateral Flow AssaysPolymerase Chain Reaction-based DiagnosticsRapid Diagnostic AssaysReverse Transcription Polymerase Chain Reaction (Rt-pcr)Viral Antigen Detection
The SARS-CoV-2 pandemic has created an unprecedented need for rapid diagnostic testing to enable the efficient treatment and mitigation of COVID-19. The primary diagnostic tool currently employed is reverse transcription polymerase chain reaction (RT-PCR), which can have good sensitivity and excellent specificity. Unfortunately, implementation costs and logistical problems with reagents during the global SARS-CoV-2 pandemic have hindered its universal on demand adoption. Lateral flow assays (LFAs) represent a class of diagnostic that, if sufficiently clinically sensitive, may fill many of the gaps in the current RT-PCR testing regime, especially in low- and middle-income countries (LMICs). To date, many serology LFAs have been developed, though none meet the performance requirements necessary for diagnostic use cases, primarily due to the relatively long delay between infection and seroconversion. However, on the basis of previously reported results from SARS-CoV-1, antigen-based SARS-CoV-2 assays may have significantly better clinical sensitivity than serology assays. To date, only a very small number of antigen-detecting LFAs have been developed. Development of a half-strip LFA is a useful first step in the development of any LFA format. In this work, we present a half-strip LFA using commercially available antibodies for the detection of SARS-CoV-2. We have tested this LFA in buffer and measured an LOD of 0.65 ng/mL (95% CI of 0.53 to 0.77 ng/mL) ng/mL with recombinant antigen using an optical reader with sensitivity equivalent to a visual read. Further development, including evaluating the appropriate sample matrix, will be required for this assay approach to be made useful in a point of care setting, though this half-strip LFA may serve as a useful starting point for others developing similar tests.
16
A Novel Coronavirus from Patients with Pneumonia in China, 2019
Na Zhu, Dingyu Zhang, Xingwang Li et al. · New England Journal of Medicine · 2020 · 30.4K citations · Full text
First Case of 2019 Novel Coronavirus in the United States
Michelle Holshue, Chas DeBolt, Scott Lindquist et al. · New England Journal of Medicine · 2020 · 6.4K citations · Full text
Dose-Response Analysis Using R
Christian Ritz, Florent Baty, J. C. Streibig et al. · PLoS ONE · 2015 · 3.7K citations · Full text
Antibody responses to SARS-CoV-2 in patients with COVID-19
Quanxin Long, Bai-Zhong Liu, Haijun Deng et al. · Nature Medicine · 2020 · 3.1K citations · Full text
Limit of blank, limit of detection and limit of quantitation.
David Armbruster, Terry Pry · PubMed · 2008 · 2.1K citations · Full text