IEEE Transactions on Industrial Electronics · 2020 · 48 citations · 31 references
EngineeringMechanical EngineeringMicroelectromechanical SystemsSensorsVentilationFlow SensorsMems SensorsMicroelectromechanical SensorsTemperature MeasurementTemperature SensorsThermal SensorsAirflow MeasurementMems Flow SensorsMems Thermal SensorsPersonalized VentilationPower ConsumptionSensitivityThermal Flow SensorsVentilation Sensors
The study investigates a thermoresistive micro‑calorimetric flow sensor fabricated in 0.35‑µm CMOS MEMS technology with two packaging designs, open‑space (O‑type) and probe‑with‑channel (P‑type). The P‑type sensor is built on a two‑polysilicon, four‑metal CMOS MEMS process, packaged with a wireless multisensor module for personalized ventilation and predicted mean vote monitoring in HVAC systems. The P‑type design delivers 80 % higher sensitivity than the O‑type, a normalized sensitivity of 228 µV (m s⁻¹)⁻¹ mW⁻¹, power consumption below 4.2 mW, ±0.05 m s⁻¹ accuracy over –2 to 2 m s⁻¹, and <0.2 % repeatability, confirming its suitability for indoor airflow measurement in variable ambient environments.
In this article, by using 0.35-μm two-polysilicon four-metal CMOS MEMS technology, a thermoresistive micro calorimetric flow (TMCF) sensor with two packaging designs is systematically investigated: Open-space (O-type) and probe-with-channel (P-type) designs. In comparison with the O-type design, the P-type sensor shows an 80% enhanced sensitivity with a relieved tilt angle effect on the mainstream airflow detection. Accordingly, the P-type packaged flow sensor for HVAC gains a prominent normalized sensitivity (S*) of 228 μV/(m/s)/mW, while also having a low power consumption (P) of less than 4.2 mW. Moreover, within the linear range of -2 to 2 m/s, an accuracy of ±0.05 m/s is achieved, thus enabling this robust flow sensor (repeatability <; 0.2%) for indoor airflow measurements even in a variable ambient environment. Furthermore, the proposed P-type TMCF sensor and its wireless multisensor module are applied for the development of personalized ventilation and the monitoring of predicted mean vote, both of which confirm the functionality of the developed sensor for indoor airflow measurements in the HVAC system.
31
Micromachined Thermal Flow Sensors—A Review
Jonathan T. W. Kuo, Lawrence Yu, Ellis Meng · Micromachines · 2012 · 461 citations · Full text
Engineering, Materials Engineering, Mechanical Engineering +17
Micromachined thermally based CMOS microsensors
H. Baltes, Oliver Paul, Oliver Brand · Proceedings of the IEEE · 1998 · 259 citations
Micromachined Flow Sensors in Biomedical Applications
Sergio Silvestri, Emiliano Schena · Micromachines · 2012 · 130 citations · Full text