EPJ Web of Conferences · 2020 · 19 citations · 2 references
EngineeringNuclear EngineeringPhysicsInstrumentationNuclear InstrumentationSpectroscopyAccelerator ArchitectureAccelerator PhysicsNeutron DetectionRadiation SpectroscopyReactor InstrumentationAcceleratorsModes Of OperationMonte Carlo Instrument SimulationsPowder DiffractionPowder Diffraction AnalysisPowder Neutron DiffractionPowder X-ray DiffractionTime-of-flight Spectroscopy
We describe the Compact Accelerator-based Neutron Source SONATE which we are aiming for to replace the closed Orphée reactor at Saclay, France. The SONATE source would serve an instrumental suite of about 10 instruments. The instruments would be split into low resolution instruments and higher resolution instruments. Our reference design is based on a proton accelerator operating at an energy in the range 20-30 MeV. The accelerator would serve 2 target stations. The first one operating at 20Hz with 2ms long pulses serving low resolution instruments (SANS, reflectivity, imaging, spin-echo) and the second one operating at 100Hz, 200μs long pulses serving higher resolution instruments (powder diffraction, Direct Time-of-flight spectroscopy, Indirect geometry spectroscopy). The 2 operation modes would be interlaced. The peak current on the target is aimed at 100 mA with an average power on the target on the order of 50-80 kW. Numerical Monte-Carlo simulations show that we may expect instrument performances equivalent to the current instruments around Orphée or ISIS.
2
Low dimensional neutron moderators for enhanced source brightness
F. Mezei, L. Zanini, A. Takibayev et al. · Journal of Neutron Research · 2014 · 62 citations · Full text