Journal of Oncology · 2020 · 116 citations · 41 references
Natural SciencesOncologyBiophotonicsSpectroscopic AnalysisSpectroscopyAbsorption SpectroscopyInfrared SpectroscopyOptical DiagnosticsOptical SpectroscopySalivary BiomarkersAttenuated Total ReflectanceBiomarker DetectionFourier Transform Infrared SpectroscopyInfrared SpectraSaliva-based ScreeningSalivary Biomarker AnalysisSalivary Biomarker DiagnosisSalivary Cancer Biomarkers
Saliva biomarkers using reagent-free biophotonic technology have not been investigated as a strategy for early detection of breast cancer (BC). The attenuated total reflection-Fourier transform infrared (ATR-FTIR) spectroscopy has been proposed as a promising tool for disease diagnosis. However, its utilization in cancer is still incipient, and currently saliva has not been used for BC screening. We have applied ATR-FTIR onto saliva from patients with breast cancer, benign breast disease, and healthy matched controls to investigate its potential use in BC diagnosis. Several salivary vibrational modes have been identified in original and second-derivative spectra. The absorbance levels at wavenumber 1041 cm −1 were significantly higher (<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M1"><mml:mrow><mml:mi>p</mml:mi><mml:mo><</mml:mo><mml:mn>0.05</mml:mn></mml:mrow></mml:math>) in saliva of breast cancer patients compared with those of benign patients, and the ROC curve analysis of this peak showed a reasonable accuracy to discriminate breast cancer from benign and control patients. The 1433–1302.9 cm −1 band area was significantly higher (<mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="M2"><mml:mrow><mml:mi>p</mml:mi><mml:mo><</mml:mo><mml:mn>0.05</mml:mn></mml:mrow></mml:math>) in saliva of breast cancer patients than in control and benign patients. This salivary ATR-FTIR spectral area was prevalidated as a potential diagnostic biomarker of BC. This spectral biomarker was able to discriminate human BC from controls with sensitivity and specificity of 90% and 80%, respectively. Besides, it was able to differentiate BC from benign disease with sensitivity and specificity of 90% and 70%, respectively. Briefly, for the first time, saliva analysis by ATR-FTIR spectroscopy has demonstrated the potential use of salivary spectral biomarkers (1041 cm −1 and 1433–1302.9 cm −1 ) as a novel alternative for noninvasive BC diagnosis, which could be used for screening purposes.
41
Catherine Van Poznak, Mark R. Somerfield, Robert C. Bast et al. · Journal of Clinical Oncology · 2015 · 394 citations · Full text
Infrared spectroscopy and microscopy in cancer research and diagnosis.
G. Bellisola, Claudio Sorio · PubMed · 2012 · 277 citations
Evaluation of FTIR Spectroscopy as a diagnostic tool for lung cancer using sputum
Paul D. Lewis, Keir Lewis, Robin Ghosal et al. · BMC Cancer · 2010 · 200 citations · Full text