The Analyst · 2019 · 21 citations · 30 references
PharmacyPharmaceutical AnalysisPharmaceuticsAnalytical ChemistryMass Spectrometric AnalysisMonoclonal AntibodiesAntibody CharacterizationBioanalytical Method ValidationDiagnostic Monoclonal AntibodiesEnzyme-linked Immunosorbent AssayImmunoassay AnalysisMicrofluidicsAnalytical Methods DevelopmentBioanalysis Of Monoclonal AntibodiesCapillary ElectrophoresisCapillary Electrophoresis Method DevelopmentDigestionEnzymatic DigestionIn-line AnalysisMicroreactor Technology
Monoclonal antibodies (mAbs) are undergoing rapid growth in the pharmaceutical industry due to their clinical efficiency. Concomitantly, robust, cost-effective, and high throughput analytical methods are needed for their quality control. Among all analytical techniques, capillary electrophoresis (CE) presents alternative and attractive features because the capillary can be used both as a microreactor and as a support for separation. Transverse diffusion of laminar flow profiles was applied for the middle-up analysis of mAbs for the first time. Infliximab was selected as the model mAb. All middle-up analysis steps (enzymatic digestion, electrophoretic separation and UV detection) were integrated into the same capillary. The conditions for the separation of infliximab subunits (pH, ionic strength, and type of background electrolyte) and in-line digestion parameters (reactant injection conditions, time, temperature and enzyme/mAb ratio) were optimized. The in-line methodology was compared to the off-line methodology and evaluated in terms of proteolysis efficiency, repeatability, and applicability to different mAbs. Finally, the methodology was transferred to capillary electrophoresis coupled to mass spectrometry (sheathless interface) to identify infliximab subunits. The in-line methodology was successfully implemented with a simplified injection scheme, temperature control, fast enzymatic reaction and high resolution of separation of infliximab subunits under pseudo-native MS compatible conditions. In comparison with the off-line methodology, reactant consumption was reduced by a factor of 1000, and the numbers of theoretical plates were increased by a factor of 2.
30
Bjarne Vincents, Ulrich von Pawel‐Rammingen, Lars Björck et al. · Biochemistry · 2004 · 145 citations
A new tool for monoclonal antibody analysis
Yan An, Ying Zhang, Hans-Martin Mueller et al. · mAbs · 2014 · 143 citations · Full text
Erin A. Redman, Nicholas G. Batz, J. Scott Mellors et al. · Analytical Chemistry · 2015 · 127 citations
Pharmacy, Biochemistry, Chemistry +16