PLoS ONE · 2019 · 12 citations · 27 references
MedicineRadiologyDiagnostic ImagingDiagnostic RadiologyHybrid ImagingAbdominal ImagingComputed TomographyImage QualityImage Quality AssessmentImage ReconstructionMedical ImagingHybrid ReconstructionImage DenoisingImage Noise AssessmentImage Noise ReductionIterative Image ReconstructionIterative ReconstructionReconstruction Quality AssessmentSubjective Image Quality Assessment
The purpose of this study was to investigate whether the novel image-based noise reduction software (NRS) improves image quality, and to assess the feasibility of using this software in combination with hybrid iterative reconstruction (IR) in image quality on thin-slice abdominal CT. In this retrospective study, 54 patients who underwent dynamic liver CT between April and July 2017 and had a body mass index higher than 25 kg/m2 were included. Three image sets of each patient were reconstructed as follows: hybrid IR images with 1-mm slice thickness (group A), hybrid IR images with 5-mm slice thickness (group B), and hybrid IR images with 1-mm slice thickness denoised using NRS (group C). The mean image noise and contrast-to-noise ratio relative to the muscle of the aorta and liver were assessed. Subjective image quality was evaluated by two radiologists for sharpness, noise, contrast, and overall quality using 5-point scales. The mean image noise was significantly lower in group C than in group A (p < 0.01), but no significant difference was observed between groups B and C. The contrast-to-noise ratio was significantly higher in group C than in group A (p < 0.01 and p = 0.01, respectively). Subjective image quality was also significantly higher in group C than in group A (p < 0.01), in terms of noise and overall quality, but not in terms of sharpness and contrast (p = 0.65 and 0.07, respectively). The contrast of images in group C was greater than that in group A, but this difference was not significant. Compared with hybrid IR alone, the novel NRS combined with a hybrid IR could result in significant noise reduction without sacrificing image quality on CT. This combined approach will likely be particularly useful for thin-slice abdominal CT examinations of overweight patients.
27
The National Comprehensive Cancer Network
William T. McGivney · Cancer · 1998 · 16.9K citations
The Essential Physics of Medical Imaging
Jerrold T. Bushberg, J. Anthony Seibert, Edwin M. Leidholdt et al. · Medical Physics · 2003 · 2K citations · Full text
Natural Sciences, Physics, Radiology +14
Daniele Marin, Rendon C. Nelson, Sebastian T. Schindera et al. · Radiology · 2009 · 490 citations