Analytical Chemistry · 2019 · 18 citations · 29 references
Natural SciencesBiochemistryBiophysicsBiophotonicsBiosensorsSpectroscopyOptical BiosensingOptical BiosensorsOptical DiagnosticsOptical SpectroscopyProtein CharacterizationProtein QuantificationFrequency-domain MeasurementOptical DetectionProtein BiosensingProtein Content Determination
In this paper, we propose a linear differential detection system based on a frequency domain weak measurement. The system can be used for detecting optical substances. Moreover, we completed an experiment to detect himan serum albumin (HSA) content in a mixture of human serum albumin and l-proline via dialysis. This work also proves the differential function of the system. This experiment can be further extended to detecting protein content in a mixed solution that contains protein macromolecules and various small molecules. It is very important for detecting molecules without photomarking in solutions of complex biological samples. In this paper, the system has an optical resolution of 1.39 × 10–5, and resolution of 4.06 × 10–8 mol/L for himan serum protein solution.
29
Ultrasensitive Beam Deflection Measurement via Interferometric Weak Value Amplification
P. Ben Dixon, David J. Starling, Andrew N. Jordan et al. · Physical Review Letters · 2009 · 774 citations · Full text
Engineering, Physics, Actuators +16
Realization of a measurement of a ‘‘weak value’’
Nicholas W. M. Ritchie, J. G. Story, Randall G. Hulet · Physical Review Letters · 1991 · 595 citations
Natural Sciences, Physics, Optics +11