Assessment Of The Radiometric Accuracy In A Target Less Work Flow Using Pix4D Software

Manuel Cubero-Castan, K. Schneider-Zapp, M. Bellomo, Christoph Strecha

2018 · 22 citations · 5 references

Concepts

Abstract

To compute reflectance from images taken by multispectral sensors aboard UAVs, most users perform radiometric calibration using a target with known reflectance. This workflow is error-prone and not practical for large data acquisitions. With recent advances in multispectral cameras, sensors which measure the sky down-welling irradiance have become available. This enables radiometric calibration without using a target. In this paper, we assess the radiometric accuracy of target less acquisition using a Sequoia + camera <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1</sup> for both at-ground and in-flight measurements. Most of the measured control points exhibit a high correlation of 0.98 in the computed reflectance factor with respect to the expected values.

References