Journal of Synchrotron Radiation · 2019 · 60 citations · 33 references
EngineeringChemistryPhotonicsRadiation DetectionRadiation MeasurementUltraviolet DetectorsX-ray DetectionX-ray DetectorsX-ray OpticsBeam Position MonitoringFree-electron Laser X-raysFree-electron LasersPhoton EnergyRadiation Detection EfficiencyRadiation IntensityVacuum Ultraviolet DetectorsX-ray Diagnostics
A novel X-ray gas monitor (XGM) has been developed which allows the measurement of absolute photon pulse energy and photon beam position at all existing and upcoming free-electron lasers (FELs) over a broad spectral range covering vacuum ultraviolet (VUV), extreme ultraviolet (EUV) and soft and hard X-rays. The XGM covers a wide dynamic range from spontaneous undulator radiation to FEL radiation and provides a temporal resolution of better than 200 ns. The XGM consists of two X-ray gas-monitor detectors (XGMDs) and two huge-aperture open electron multipliers (HAMPs). The HAMP enhances the detection efficiency of the XGM for low-intensity radiation down to 10 5 photons per pulse and for FEL radiation in the hard X-ray spectral range, while the XGMD operates in higher-intensity regimes. The relative standard uncertainty for measurements of the absolute photon pulse energy is well below 10%, and down to 1% for measurements of relative pulse-to-pulse intensity on pulses with more than 10 10 photons per pulse. The accuracy of beam-position monitoring in the vertical and horizontal directions is of the order of 10 µm.
33
Gas detectors for x-ray lasers
K. Tiedtke, J. Feldhaus, Ulrich Hahn et al. · Journal of Applied Physics · 2008 · 179 citations · Full text
Engineering, Physics, Optics +16