IEEE Transactions on Circuits & Systems II Express Briefs · 2019 · 27 citations · 12 references
EngineeringElectrical EngineeringMicroelectronicsPower ElectronicsSystem-on-chip DesignCmos Circuit DesignConverter TopologiesDc-dc ConvertersHigh-frequency Semiconductor DevicesRadio-frequency Integrated CircuitsVoltage ScalingBuck ConvertersCmos ScalingDynamic ScalingDynamic Voltage And Frequency ScalingHigh-frequency OperationPower DensityRecovery TimeRf Cmos Design
This brief proposes a buck converter with adaptive constant on time (ACOT) control, including transient-enhanced technique for fast dynamic voltage scaling (DVS) and load-transient response in RF applications. The proposed ACOT control achieves high performance in DVS tracking response to shorten up-tracking time and down-tracking time. Moreover, the high bandwidth transient-enhanced technique in ACOT control improves load-transient response suffering from low bandwidth compensation loop. In addition, the proposed buck converter operates at 2.5 MHz for high power density and 90.1% peak efficiency. This brief is implemented by TSMC 0.18 μm 1P6M CMOS technology with a chip area 1.81 mm2. Measurement results achieve that the output voltage have both 0.6 μs and 0.6 μs recovery time in 600 mA step-up load and 600 mA step-down load, respectively. For 0.6 V step, the output voltage have both 2 μs in up-tracking time and down-tracking time.
12