Journal of Extracellular Vesicles · 2019 · 626 citations · 31 references
Life SciencesBiophysicsCell BiologyNanobiotechnologyNanomaterialsSensorsCell-nanoparticle InteractionsExosome AnalysisNanoparticle CharacterizationAccuracyExtracellular Vesicle ImagingExtracellular Vesicle QuantificationExtracellular Vesicle ReleaseNanoparticle Tracking AnalysisNanoparticle-based SensingRepeatabilityRepeatability Estimation
ABSTRACT The expanding field of extracellular vesicle (EV) research needs reproducible and accurate methods to characterize single EVs. Nanoparticle Tracking Analysis (NTA) is commonly used to determine EV concentration and diameter. As the EV field is lacking methods to easily confirm and validate NTA data, questioning the reliability of measurements remains highly important. In this regard, a comparison addressing measurement quality between different NTA devices such as Malvern's NanoSight NS300 or Particle Metrix' ZetaView has not yet been conducted. To evaluate the accuracy and repeatability of size and concentration determinations of both devices, we employed comparative methods including transmission electron microscopy (TEM) and single particle interferometric reflectance imaging sensing (SP‐IRIS) by ExoView. Multiple test measurements with nanospheres, liposomes and ultracentrifuged EVs from human serum and cell culture supernatant were performed. Additionally, serial dilutions and freeze‐thaw cycle‐dependent EV decrease were measured to determine the robustness of each system. Strikingly, NanoSight NS300 exhibited a 2.0–2.1‐fold overestimation of polystyrene and silica nanosphere concentration. By measuring serial dilutions of EV samples, we demonstrated higher accuracy in concentration determination by ZetaView (% BIAS range: 2.7–8.5) in comparison with NanoSight NS300 (% BIAS range: 32.9–36.8). The concentration measurements by ZetaView were also more precise (% CV range: 0.0–4.7) than measurements by NanoSight NS300 (% CV range: 5.4–10.7). On the contrary, quantitative TEM imaging indicated more accurate EV sizing by NanoSight NS300 (% D TEM range: 79.5–134.3) compared to ZetaView (% D TEM range: 111.8–205.7), while being equally repeatable (NanoSight NS300% CV range: 0.8–6.7; ZetaView: 1.4–7.8). However, both devices failed to report a peak EV diameter below 60 nm compared to TEM and SP‐IRIS. Taken together, NTA devices differ strongly in their hardware and software affecting measuring results. ZetaView provided a more accurate and repeatable depiction of EV concentration, whereas NanoSight NS300 supplied size measurements of higher resolution.
31
Clotilde Théry, Kenneth W. Witwer, Elena Aïkawa et al. · Journal of Extracellular Vesicles · 2018 · 11.2K citations · Full text
Pancreatic cancer exosomes initiate pre-metastatic niche formation in the liver
Bruno Costa‐Silva, Nicole M. Aiello, Allyson J. Ocean et al. · Nature Cell Biology · 2015 · 2.7K citations · Full text
Medicine, Cancer Biology, Oncology +14
Jan Lötvall, Andrew F. Hill, Fred H. Hochberg et al. · Journal of Extracellular Vesicles · 2014 · 2.7K citations · Full text