MedicinePathologyCytopathologyDiagnostic PathologySurgical PathologyCytologyFine-needle Aspiration CytologyMedical ImagingMicroscopic ExaminationPancreatic CytologyThyroid CytologyComparative Diagnostic PerformanceConventional MicroscopyFna CytologyLung Fine-needle Aspiration CytologyLymph Node Fine-needle Aspiration CytologyNeedle Aspiration BiopsySalivary Gland Fine-needle Aspiration CytologyThyroid Fine-needle Aspiration Cytology
BACKGROUND: The current technology for remote assessment of fine-needle aspiration-rapid on-site evaluation (FNA-ROSE) is limited. Recent advances may provide solutions. This study compared the performance of VisionTek digital microscope (VDM) (Sakura, Japan) and Hamamatsu NanoZoomer C9600-12 single Z-stack digital scan (SZDS) to conventional light microscopy (CLM) for FNA-ROSE. METHODS: = 1) based on a single institution's routine workflow. One Diff-Quik-stained slide was selected for each case. Two board-certified cytopathologists independently evaluated the cases using VDM, SZDS, and CLM. A "washout" period of at least 14 days was placed between the reviews. The results were categorized into satisfactory versus unsatisfactory for adequacy assessment (AA) and unsatisfactory, benign, atypical, suspicious, and malignant for preliminary diagnosis (PD). RESULTS: For AA, the Cohen's kappa statistics (CKS) scores of intermodality agreement (IMA) were 0.74-0.94 (CLM vs. VDM) and 0.86-1 (CLM vs. SZDS). The discordant rates of IMA were 3.3% (4/120) for VDM versus CLM, and 1.7% (2/120) for SZDS versus CLM. For PD, the CKS scores of IMA ranged 0.7-0.93. The overall discordant rates of IMA were 15% (18/120) for CLM versus VDM and 10.8% (13/120) for CLM versus SZDS. The discordant rates of IMA with 2 or higher degrees were 5.8% (7/120) for CLM versus VDM and 1.7% (2/120) for CLM versus SZDS. The average time spent per slide was 270 s for VDM, significantly longer than that for CLM (113 s) or for SZDS (122 s). CONCLUSIONS: Our data demonstrate that both VDM and SZDS are suitable to provide AA and reasonable PD evaluation. VDM, however, has a significantly longer turnaround time and worse diagnostic performance. The study demonstrates both the potentials and challenges of using VDM and SZDS for FNA-ROSE.
11
Liron Pantanowitz, John H. Sinard, Walter H. Henricks et al. · Archives of Pathology & Laboratory Medicine · 2013 · 603 citations · Full text
Medicine, Hematology, Pathology +16
Sources of diagnostic error in fine needle aspiration of the thyroid
Thomas L. Hall, Lester J. Layfield, Anne Philippe et al. · Cancer · 1989 · 280 citations