PLoS ONE · 2018 · 20 citations · 20 references
Health ProfessionsOphthalmologyVision ScienceOcular DiseaseOcular ImagingOcular PathologyGlaucomaGlaucoma MonitoringMacular DiseaseMacular ImagingOptical Coherence TomographyRetinal ImagingEpiretinal Membrane ImagingGanglion Cell Layer ImagingGanglion Cell LossGlaucoma PrevalenceGlaucoma ProgressionGlaucoma SurveillanceRetinal Ganglion Cell DisordersRetinal Ganglion Cell Imaging
PURPOSE: The ganglion cell analysis (GCA) of the CIRRUSTM HD-OCT (Carl Zeiss, Meditec; Dublin, CA) provides measurement of the macular ganglion cell-inner plexiform layer (GCIPL) thickness. This study determined the frequency of scan artefacts and errors in GCIPL imaging in individuals undergoing HD-OCT surveillance for glaucoma. METHOD: A total of 1439 eyes from 721 subjects enrolled in a prospective study assessing predictors of glaucoma progression underwent macular GCIPL imaging with the CIRRUS HD-OCT at recruitment. The prevalence of acquisition errors, segmentation errors, and co-morbid macular pathology was determined. RESULTS: A total of 87 (6.0%) of the 1439 scans had either acquisition errors, segmentation artefacts, or other macular pathology. The most common co-morbid macular pathology was epiretinal membrane in 2.2% of eyes. CONCLUSION: The macular GCIPL scan was artefact free in 94% of eyes. However, epiretinal membrane and high myopia can cause scan artefact and should be considered when interpreting the results.
20
Prevalence and Associations of Epiretinal Membranes
Wayne Smith, Tien Chey, Jie Jin Wang et al. · Ophthalmology · 1997 · 503 citations
Jean-Claude Mwanza, Jonathan D. Oakley, Donald L. Budenz et al. · Investigative Ophthalmology & Visual Science · 2011 · 425 citations · Full text