Tissue Engineering Part A · 2018 · 16 citations · 40 references
EngineeringBioengineeringBiomedical EngineeringBiomaterialsTissue EngineeringVascular SurgeryBiomaterials For Tissue EngineeringCardiovascular BiomaterialsPolymeric BiomaterialsScaffold DesignTissue Engineering ScaffoldsVascular RegenerationDegradationExtracellular Matrix DegradationPoly(glycolic Acid)Poly(glycolic Acid) DegradationVascular Graft BiomaterialsVascular Tissue EngineeringVascular Tissue Engineering BiomaterialsVascularization
Tissue-engineered vascular grafts (TEVGs) have shown significant promise; however, progression toward clinical application has been limited by the use of slow degrading polymers, which cause prolonged inflammatory responses and alter remodeling. Thus, a significant need persists to develop a vascular graft that is easily implanted, withstands the mechanical stresses of arterial flow, and quickly degrades after remodeling. We utilized textile technology to braid a TEVG comprised exclusively of rapidly degrading poly(glycolic acid). Implantation in an in vivo rat abdominal aorta model demonstrated near complete degradation of the initial TEVG scaffold by 6 months and formation of a neoartery with continuous endothelium, contractile smooth muscle cells, extracellular matrix deposition, and mechanical properties comparable to native aorta. Furthermore, coating of the braided poly(glycolic acid) TEVG with poly(glycerol sebacate) led to decreased calcification in the resultant neoartery. These novel results warrant further studies and may aid in the development of the ideal degradable vascular graft. We utilized innovative textile technology to create tissue-engineered vascular grafts (TEVGs) comprised exclusively of rapidly degrading material poly(glycolic acid). Our new technology led to robust neotissue formation in the TEVGs, especially extracellular matrix formation, such as elastin. In addition, the rapid degradation of the polymer significantly reduced complications, such as stenosis or calcification, as seen with the use of slow degrading polymers in the majority of previous studies for aortic small diameter TEVGs.
40
Heart Disease and Stroke Statistics—2015 Update
Dariush Mozaffarian, Emelia J. Benjamin, Alan S. Go et al. · Circulation · 2014 · 5.8K citations
A tough biodegradable elastomer
Yadong Wang, Guillermo A. Ameer, Barbara J. Sheppard et al. · Nature Biotechnology · 2002 · 1.3K citations
Natural Sciences, Materials Engineering, Materials Science +10
Human tissue-engineered blood vessels for adult arterial revascularization
Nicolas L’Heureux, Nathalie Dusserre, Gerhardt König et al. · Nature Medicine · 2006 · 1.1K citations · Full text
Engineering, Bioengineering, Surgery +14
The in vivo degradation, absorption and excretion of PCL-based implant
Hongfan Sun, Lin Mei, Cunxian Song et al. · Biomaterials · 2005 · 962 citations
Natural Sciences, Biomedical Engineering, Pharmacokinetics +14
Gerhardt König, Todd N. McAllister, Nathalie Dusserre et al. · Biomaterials · 2008 · 570 citations · Full text