Glucose Management during Insulinoma Resection Using Real-Time Subcutaneous Continuous Glucose Monitoring

Yuki Sugiyama, Chiaki Kiuchi, M. Suzuki, Yuki Maruyama, Ryo Wakabayashi, Yasunari Ohno, Shugo Takahata, Takumi Shibazaki, Mikito Kawamata

Case Reports in Anesthesiology · 2018 · 13 citations · 11 references

DOIFull text

Open access

Concepts

Abstract

Insulinoma is a rare neuroendocrine tumor that causes hypoglycemia due to unregulated insulin secretion. Blood glucose management during insulinoma resection is therefore challenging. We present a case in which real-time subcutaneous continuous glucose monitoring (SCGM) in combination with intermittent blood glucose measurement was used for glycemic control during surgery for insulinoma resection. The SCGM system showed the trends and peak of interstitial glucose in response to glucose loading and the change of interstitial glucose before and after insulinoma resection. These data were helpful for adjusting the glucose infusion; therefore, we think that an SCGM system as a supportive device for glucose monitoring may be useful for glucose management during surgery.

References

11