Diabetes Technology & Therapeutics · 2013 · 46 citations · 19 references
EngineeringBioengineeringBiomedical EngineeringBiomedical Signal ProcessingBiosensorsDiabetologyBiosensor CalibrationBlood Glucose MonitoringContinuous Glucose MonitoringGlycemic ControlGlycemic MonitoringMedical Device CalibrationBlood Glucose Meter AccuracyGlucose Measurement CalibrationGlucose MonitoringGlucose Monitoring DevicesPoint-of-care Glucose Measurement
OBJECTIVE: Accurate real-time continuous glucose measurements may improve glucose control in the critical care unit. We evaluated the accuracy of the FreeStyle(®) Navigator(®) (Abbott Diabetes Care, Alameda, CA) subcutaneous continuous glucose monitoring (CGM) device in critically ill adults using two methods of calibration. SUBJECTS AND METHODS: In a randomized trial, paired CGM and reference glucose (hourly arterial blood glucose [ABG]) were collected over a 48-h period from 24 adults with critical illness (mean±SD age, 60±14 years; mean±SD body mass index, 29.6±9.3 kg/m(2); mean±SD Acute Physiology and Chronic Health Evaluation score, 12±4 [range, 6-19]) and hyperglycemia. In 12 subjects, the CGM device was calibrated at variable intervals of 1-6 h using ABG. In the other 12 subjects, the sensor was calibrated according to the manufacturer's instructions (1, 2, 10, and 24 h) using arterial blood and the built-in point-of-care glucometer. RESULTS: In total, 1,060 CGM-ABG pairs were analyzed over the glucose range from 4.3 to 18.8 mmol/L. Using enhanced calibration median (interquartile range) every 169 (122-213) min, the absolute relative deviation was lower (7.0% [3.5, 13.0] vs. 12.8% [6.3, 21.8], P<0.001), and the percentage of points in the Clarke error grid Zone A was higher (87.8% vs. 70.2%). CONCLUSIONS: Accuracy of the Navigator CGM device during critical illness was comparable to that observed in non-critical care settings. Further significant improvements in accuracy may be obtained by frequent calibrations with ABG measurements.
19
Evaluating Clinical Accuracy of Systems for Self-Monitoring of Blood Glucose
William L. Clarke, Daniel J. Cox, Linda Gonder‐Frederick et al. · Diabetes Care · 1987 · 1.4K citations
Medicine, Endocrinology, Biosensors +16
Effect of Continuous Glucose Monitoring on Hypoglycemia in Type 1 Diabetes
Tadej Battelino, Moshe Phillip, Nataša Bratina et al. · Diabetes Care · 2011 · 491 citations · Full text
The Effect of Continuous Glucose Monitoring in Well-Controlled Type 1 Diabetes
Diabetes Care · 2009 · 397 citations · Full text
Medicine, Endocrinology, Pediatrics +17