CORROSION · 2018 · 34 citations · 6 references
Natural SciencesMaterials ScienceCorrosion ScienceElectrochemical EngineeringElectrochemistryCorrosion EngineeringCorrosion MechanismsCorrosion Of SteelsCorrosion TestingCrevice CorrosionElectrochemical CorrosionCorrosion CellsCorrosion Potential TestingCrevice Corrosion Of Stainless SteelsCrevice Corrosion TestingCyclic Polarization TestingElectrochemical Corrosion AnalysisElectrochemical Corrosion TestingPotentiodynamic Polarization
A very simple electrochemical cell for corrosion experiments has been developed using a syringe as the cell with the syringe plunger replaced by reference and counter electrodes. Because the exposed area is defined by a hanging droplet, no masking is required and thus no crevice corrosion forms. This cell therefore enables measurements of pitting potentials of metals that are susceptible to crevice corrosion. The method was validated by cyclic potentiodynamic polarization experiments on Type 304H stainless steel. Crevice or interfacial corrosion was not evident in multiple replicate specimens tested with the syringe cell method.
6
New electrochemical cell for pitting corrosion testing
R. Ovarfort · Corrosion Science · 1988 · 136 citations
Natural Sciences, Materials Engineering, Materials Science +12