IEEE Transactions on Biomedical Circuits and Systems · 2017 · 13 citations · 21 references
EngineeringBiomedical EngineeringElectrical EngineeringAntennasLow-power DesignMicrowave EngineeringAntenna Impedance MatchingImpedance MatchingImpedance Matching CircuitsMicrowave Network AnalysisRadio-frequency Integrated CircuitsWireless Power TransferAccuracyBalun IntegrationBalun Matching NetworksImpedance Matching NetworksMatching CircuitsMatching Network OptimizationNoise FigureTunable Matching Networks
A low-power impedance detection method using a hybrid transformer and its analysis are presented. A balun is reused for the hybrid transformer to achieve area-efficiency. The complex impedance detection enables faster optimization on a tunable matching network and its calibration technique increases the detection accuracy. The proposed impedance detection method fabricated in a 40-nm CMOS process consumes only 0.83 mW and demonstrates the accuracy of less than 18° and 0.1 on the Γ detection up to of 0.5 in ISM2.4 GHz band. After single-step matching network tuning, PA power and RX noise figure are improved by up to 1.2 dB and 1.3 dB, respectively.
21
Sang-Min Yoo, Jeffrey S. Walling, Eum Chan Woo et al. · IEEE Journal of Solid-State Circuits · 2011 · 206 citations
J. deMingo, Antonio Valdovinos, Antonio Crespo et al. · IEEE Transactions on Microwave Theory and Techniques · 2004 · 201 citations