Frontiers in Neurorobotics · 2017 · 47 citations · 40 references
MedicineOrthopedic SurgeryRehabilitation MedicineAmputee RehabilitationMotor ControlProstheticsAnkle BiomechanicsBalance RehabilitationLower Extremity RehabilitationLower-limb ProstheticsProsthetic BiomechanicsProsthetic RehabilitationAnkle-foot Prosthesis BiomechanicsBiomechanics Of Amputee WalkingLower-limb Prosthetic ControlPowered Ankle-foot ProsthesesProsthetic Limb ControlProsthetic Limb FunctionProsthetic Lower Limb BiomechanicsStance Phase Control
Below-knee amputation is associated with higher energy expenditure during walking, partially due to difficulty maintaining balance. We previously found that once-per-step push-off work control can reduce balance-related effort, both in simulation and in experiments with human participants. Simulations also suggested that changing ankle inversion/eversion torque on each step, in response to changes in body state, could assist with balance. In this study, we investigated the effects of ankle inversion/eversion torque modulation on balance-related effort among amputees (N = 5) using a multi-actuated ankle-foot prosthesis emulator. In stabilizing conditions, changes in ankle inversion/eversion torque were applied so as to counteract deviations in side-to-side center-of-mass acceleration at the moment of intact-limb toe off; higher acceleration towards the prosthetic limb resulted in a corrective ankle inversion torque during the ensuing stance phase. Destabilizing controllers had the opposite effect, and a zero-gain controller made no changes to the nominal inversion/eversion torque. To separate the balance-related effects of step-to-step control from the potential effects of changes in average mechanics, average ankle inversion/eversion torque and prosthesis work were held constant across conditions. High-gain stabilizing control lowered metabolic cost by 13% compared to the zero-gain controller (p < 0.05). We then investigated individual responses to subject-specific stabilizing controllers following an enforced exploration period. Four of five participants experienced reduced metabolic rate compared to the zero-gain controller (-15%, -14%, -11%, -6% and +4%) an average reduction of 9% (p < 0.05). Average prosthesis mechanics were unchanged across all conditions, suggesting that improvements in energy economy might have come from changes in step-to-step corrections related to balance. Step-to-step modulation of inversion/eversion torque could be used in new, active ankle-foot prostheses to reduce walking effort associated with maintaining balance.
40
Derivation of formulae used to calculate energy expenditure in man.
Brockway Jm · PubMed · 1987 · 603 citations
Life Sciences, Nutrition, Physiology +15
Control of lateral balance in walking
At L. Hof, R Bockel, Tanneke Schoppen et al. · Gait & Posture · 2006 · 493 citations · Full text