Analytical Chemistry · 2017 · 39 citations · 32 references
Life SciencesBiochemistryMolecular BiologyProtein BiochemistryProteomicsStructural BioinformaticsChromatographyPeptide AnalysisPeptide ChemistryPeptide IdentificationProtein SeparationRetention MechanismsHydrophilic Interaction ChromatographyHydrophobic InteractionsPeptide Hydrophobicity AnalysisPeptide Retention Time PredictionPeptide SeparationRetention Time PredictionSequence Retention
The development of a peptide retention prediction model for strong cation exchange (SCX) separation on a Polysulfoethyl A column is reported. Off-line 2D LC-MS/MS analysis (SCX-RPLC) of S. cerevisiae whole cell lysate was used to generate a retention dataset of ∼30 000 peptides, sufficient for identifying the major sequence-specific features of peptide retention mechanisms in SCX. In contrast to RPLC/hydrophilic interaction liquid chromatography (HILIC) separation modes, where retention is driven by hydrophobic/hydrophilic contributions of all individual residues, SCX interactions depend mainly on peptide charge (number of basic residues at acidic pH) and size. An additive model (incorporating the contributions of all 20 residues into the peptide retention) combined with a peptide length correction produces a 0.976 R 2 value prediction accuracy, significantly higher than the additive models for either HILIC or RPLC. Position-dependent effects on peptide retention for different residues were driven by the spatial orientation of tryptic peptides upon interaction with the negatively charged surface functional groups. The positively charged N-termini serve as a primary point of interaction. For example, basic residues (Arg, His, Lys) increase peptide retention when located closer to the N-terminus. We also found that hydrophobic interactions, which could lead to a mixed-mode separation mechanism, are largely suppressed at 20–30% of acetonitrile in the eluent. The accuracy of the final Sequence-Specific Retention Calculator (SSRCalc) SCX model (∼0.99 R 2 value) exceeds all previously reported predictors for peptide LC separations. This also provides a solid platform for method development in 2D LC-MS protocols in proteomics and peptide retention prediction filtering of false positive identifications.
32
Universal sample preparation method for proteome analysis
Jacek R. Wiśniewski, Alexandre Zougman, Nagarjuna Nagaraj et al. · Nature Methods · 2009 · 8.7K citations
Selected reaction monitoring for quantitative proteomics: a tutorial
Vinzenz Lange, Paola Picotti, Bruno Domon et al. · Molecular Systems Biology · 2008 · 1.4K citations · Full text
Orthogonality of Separation in Two-Dimensional Liquid Chromatography
Martin Gilár, Petra Olivova, Amy E. Daly et al. · Analytical Chemistry · 2005 · 810 citations