GigaScience · 2017 · 325 citations · 94 references
Life SciencesMolecular BiologyBioarchaeologyGenomicsSequence AnalysisAncient DnaDegraded Dna AnalysisDna SequencingNext-generation SequencingNucleic Acid SequencingSequence Quality ControlAncient Dna SequencingDna Extraction From Degraded SamplesGc Content VariationGenomic Gc ContentLibrary Preparation For SequencingLibrary Quality AssessmentNext-generation Sequencing Library PreparationRead Quality Assessment
Ancient DNA research has been revolutionized following development of next-generation sequencing platforms. Although a number of such platforms have been applied to ancient DNA samples, the Illumina series are the dominant choice today, mainly because of high production capacities and short read production. Recently a potentially attractive alternative platform for palaeogenomic data generation has been developed, the BGISEQ-500, whose sequence output are comparable with the Illumina series. In this study, we modified the standard BGISEQ-500 library preparation specifically for use on degraded DNA, then directly compared the sequencing performance and data quality of the BGISEQ-500 to the Illumina HiSeq2500 platform on DNA extracted from 8 historic and ancient dog and wolf samples. The data generated were largely comparable between sequencing platforms, with no statistically significant difference observed for parameters including level (P = 0.371) and average sequence length (P = 0718) of endogenous nuclear DNA, sequence GC content (P = 0.311), double-stranded DNA damage rate (v. 0.309), and sequence clonality (P = 0.093). Small significant differences were found in single-strand DNA damage rate (δS; slightly lower for the BGISEQ-500, P = 0.011) and the background rate of difference from the reference genome (θ; slightly higher for BGISEQ-500, P = 0.012). This may result from the differences in amplification cycles used to polymerase chain reaction-amplify the libraries. A significant difference was also observed in the mitochondrial DNA percentages recovered (P = 0.018), although we believe this is likely a stochastic effect relating to the extremely low levels of mitochondria that were sequenced from 3 of the samples with overall very low levels of endogenous DNA. Although we acknowledge that our analyses were limited to animal material, our observations suggest that the BGISEQ-500 holds the potential to represent a valid and potentially valuable alternative platform for palaeogenomic data generation that is worthy of future exploration by those interested in the sequencing and analysis of degraded DNA.
94
A framework for variation discovery and genotyping using next-generation DNA sequencing data
Mark A. DePristo, Eric Banks, Ryan Poplin et al. · Nature Genetics · 2011 · 12.4K citations · Full text
Tandem repeats finder: a program to analyze DNA sequences
Gary Benson · Nucleic Acids Research · 1999 · 9.9K citations