Nature Communications · 2017 · 401 citations · 15 references
EngineeringBiomedical EngineeringCell BiologyBiomedical ImagingComputer VisionDigital ImagingCellular ImagingFluorescence MicroscopyImage QuantificationLight MicroscopyQuantitative Cell BiologySingle-cell VisualizationBiological ImagingQuantitative Cell ImagingQuantitative Image AnalysisSingle-cell ImagingTemporal Drift EffectsTime-lapse Data ProcessingTime-lapse ImagingTime-lapse Microscopy
Quantitative analysis of bioimaging data is often skewed by both shading in space and background variation in time. We introduce BaSiC, an image correction method based on low-rank and sparse decomposition which solves both issues. In comparison to existing shading correction tools, BaSiC achieves high-accuracy with significantly fewer input images, works for diverse imaging conditions and is robust against artefacts. Moreover, it can correct temporal drift in time-lapse microscopy data and thus improve continuous single-cell quantification. BaSiC requires no manual parameter setting and is available as a Fiji/ImageJ plugin.
15
David L. Donoho · IEEE Transactions on Information Theory · 2006 · 23.1K citations
Robust principal component analysis?
Emmanuel J. Candès, Xiaodong Li, Yi Ma et al. · Journal of the ACM · 2011 · 6.9K citations
Computer Control of Microscopes Using µManager
Arthur Edelstein, Nenad Amodaj, Karl Hoover et al. · Current Protocols in Molecular Biology · 2010 · 1.8K citations · Full text