Blood Purification · 2017 · 21 citations · 16 references
MedicineNephrologyPharmacologyDialysisHemodialysisRenal Replacement TherapyAnemia Management In HemodialysisDialysis PharmacotherapyDialyzer MembranesErythropoiesis-stimulating Agent UseErythropoiesis-stimulating TherapyHyporesponsiveness To Erythropoiesis-stimulating AgentsMulticenter TrialsOxidative Stress In HemodialysisPolysulfone MembranesResponsivenessSynthetic Dialyzer Membranes
BACKGROUND: Oxidative stress has been related to hypo-response to erythropoiesis-stimulating agents (ESAs) in hemodialysis (HD) patients. The aim of this study was to verify whether vitamin E (ViE) on a synthetic polysulfone dialyzer can improve ESA responsiveness. METHODS: This controlled, multicenter study involved 93 HD patients on stable ESA therapy, who were randomized to either ViE-coated polysulfone dialyzer or to a low-flux synthetic dialyzer. The primary outcome measure was the change in ESA resistance index (ERI) from baseline. RESULTS: Mean ERI decreased in the ViE group by 1.45 IU/kg*g/dl and increased in the control group by 0.53 IU/kg*g/dl, with a mean difference of 1.98 IU/kg*g/dl (p = 0.001 after adjusting for baseline ERI, as foreseen by the study protocol). Baseline ERI was inversely related to its changes during follow-up only in the control group (R2 = 0.29). CONCLUSIONS: The ViE dialyzer can improve ESA response in HD patients. Changes in ERI during follow-up are independent from baseline ERI only in the ViE group. Video Journal Club 'Cappuccino with Claudio Ronco' at http://www.karger.com/?doi=453442.
16
Vincenzo Panichi, A. Scatena, Alberto Rosati et al. · Nephrology Dialysis Transplantation · 2014 · 84 citations · Full text
Medicine, Nephrology, Pharmacology +14