Actuators · 2017 · 32 citations · 15 references
EngineeringCivil EngineeringActuatorsHydraulicsPerformance-based DesignActuator DesignActuator EfficiencyFlow ControlHydraulic ActuatorsHydraulic MachineryHydraulic SystemsFlow Control DevicesHydraulic Circuit DesignHydraulic CylindersHydraulic ValvesLoad-velocity RelationshipThrottlingValve ControlValves
Pump-controlled hydraulic circuits are more efficient than valve-controlled circuits, as they eliminate the energy losses due to flow throttling in valves and require less cooling effort. Presently existing pump-controlled solutions for single rod cylinders encounter an undesirable performance during certain operating conditions. This paper investigates the performance issues in common pump-controlled circuits for the single rod actuators. Detailed analysis is conducted that identifies these regions in a load-velocity plane and the factors affecting them. The findings are validated by experimental results. A new design is then proposed that employs a limited throttling valve alongside two pilot operated check valves for differential flow compensation to improve the performance. The valve is of the flow control type and is chosen to have a throttling effect over critical regions; it has the least throttling over other operating regions, thus maintaining efficiency. Experimental work demonstrates improved performance in a full operating range of the actuator as compared to a circuit that uses only the pilot-operated check valves. This circuit is energy efficient and capable of recuperating energy.
15
Energy Consumption of an LS Excavator Hydraulic System
Joshua D. Zimmerman, Matteo Pelosi, Christopher Williamson et al. · 2007 · 73 citations