IEEE Transactions on Nuclear Science · 2016 · 11 citations · 8 references
EngineeringElectrical EngineeringLow-power DesignPower ElectronicsRadiation DetectionDetector TechnologyInfrared DetectorsLow-noise Circuit DesignParticle DetectorsRadiation DetectorsSemiconductor DetectorsCharge-coupled Device DetectorsDetector DesignDetector NoiseDetector Readout ElectronicsLow-noise Detector DesignLow-noise Power Supply DesignLow-power System DesignPower System Stabilization
In high-precision detector systems, the power supply usually need to be ultra-low noise and stabilized. Design and implementation of an ultra-low noise power supply is described in this paper. We implemented and tested the power system actually in a scientific CCD (Charge-coupled device) detector system, but the design structure could be used in many high-precision detector systems as infrared detector or high-energy particles detectors. The power system uses DC-DC switching regulators and LDO regulators for power generating, uses multi-stage filters for noise reducing. Multi-output power supply with noise about 40 μV <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">rms</sub> is achieved, the overall energy efficiency is 68.5%. Besides, the electronic system takes the low temperature as an important consideration, and the system has been tested in an extreme environment as low as 193 K.
8
Direct search for low mass dark matter particles with CCDs
J. Barreto, H. Cease, H. T. Diehl et al. · Physics Letters B · 2012 · 112 citations · Full text