Analytical Chemistry · 2016 · 117 citations · 55 references
Life SciencesBiochemistryNutritional SciencesHuman NutritionMass Spectrometric AnalysisNutritional BiochemistryDietary BiomarkersFat-soluble VitaminsNutritional BiomarkersVitamin AnalysisVitamin BiochemistryWater-soluble VitaminsPlasma Micronutrient ConcentrationsSerum BiomarkersSerum Retinol LevelsSerum Tocopherol LevelsVitamin BiomarkersVitamin D BiomarkersVitamin D Status BiomarkersVitamin Status Biomarkers
Targeted metabolic profiling characterized by complementary platforms, multiplexing and low volume consumption are increasingly used for studies using biobank material. Using liquid-liquid extraction, we developed a sample workup suitable for quantification of 6 fat- and 26 water-soluble biomarkers. 50 μL of serum/plasma was mixed with dithioerythritol, ethanol, and isooctane/chloroform. The organic layer was used for analysis of the fat-soluble vitamins all-trans retinol (A), 25-hydroxyvitamin D2, 25-hydroxyvitamin D3, α-tocopherol (E), γ-tocopherol (E), and phylloquinone (K1) by LC-MS/MS. The remaining aqueous fraction was mixed with ethanol, water, pyridine, and methylchloroformate (in toluene) to derivatize the water-soluble biomarkers. The resulting toluene layer was used for GC-MS/MS analysis of alanine, α-ketoglutarate, asparagine, aspartic acid, cystathionine, total cysteine, glutamic acid, glutamine, glycine, histidine, total homocysteine, isoleucine, kynurenine, leucine, lysine, methionine, methylmalonic acid, ornithine, phenylalanine, proline, sarcosine, serine, threonine, tryptophan, tyrosine, and valine. Isotope-labeled internal standards were used for all analytes. Chromatographic run times for the LC-MS/MS and GC-MS/MS were 4.5 and 11 min, respectively. The limits of detection (LOD) for the low-concentration analytes (25-hydroxyvitamin D2, 25-hydroxyvitamin D3, and phylloquinone) were 25, 17, and 0.33 nM, respectively, while all other analytes demonstrated sensitivity significantly lower than endogenous concentrations. Recoveries ranged from 85.5-109.9% and within- and between-day coefficients of variance (CVs) were 0.7-9.4% and 1.1-17.5%, respectively. This low-volume, high-throughput multianalyte assay is currently in use in our laboratory for quantification of 32 serum/plasma biomarkers in epidemiological studies.
55
Vitamin D Deficiency and Risk of Cardiovascular Disease
Thomas J. Wang, Michael J. Pencina, Sarah L. Booth et al. · Circulation · 2008 · 2.4K citations · Full text
Zoë Maunsell, Dennis J. Wright, Sandra Rainbow · Clinical Chemistry · 2005 · 380 citations · Full text
Julie A. Schmidt, Sabina Rinaldi, Augustin Scalbert et al. · European Journal of Clinical Nutrition · 2015 · 346 citations · Full text
Increased serum kynurenine/tryptophan ratio correlates with disease progression in lung cancer
Yuzo Suzuki, Takafumi Suda, Kazuki Furuhashi et al. · Lung Cancer · 2009 · 268 citations
Medicine, Oncology, Pharmacology +7