Comparison of medical and industrial X-ray computed tomography for non-destructive testing

Anton du Plessis, S. Roux, Anina Guelpa

Case Studies in Nondestructive Testing and Evaluation · 2016 · 120 citations · 14 references

DOIFull text

Open access

Concepts

TL;DR

Industrial X‑ray CT is an emerging laboratory‑based NDT technique for samples 1–300 mm, and although microCT is preferred for its higher resolution, medical CT scanners can also yield reasonable results when ultra‑high resolution is unnecessary. The study aimed to compare medical and microCT scanners for industrial non‑destructive analysis by scanning the same test objects with both modalities. Four dense industrial test objects—a steel turbine blade, a titanium casting, a concrete cylinder with aggregate, and a concrete block with metal‑fiber reinforcement—were scanned with both medical and microCT scanners to evaluate and compare their imaging performance. The case study showed that medical CT required far shorter scan times than conventional laboratory industrial CT systems, making it a superior option for quick scout scans, high‑throughput applications, and larger objects.

Abstract

Industrial X-ray computed tomography (CT) is an emerging laboratory-based non-destructive testing technique used in a variety of applications for samples ranging from 1 mm to usually 300 mm in diameter. Usually, microCT scanners are used for industrial non-destructive testing due to the superior resolution possible compared to medical CT scanners, but it is not generally known that medical CT scanners can produce reasonable results when high resolution is not needed. As demonstrated in this case study of very dense objects, far shorter scan time is required, compared to conventional laboratory industrial CT systems, consequently being a better solution for applications such as quick scout-scans, high throughput applications and larger objects. This case study makes use of four typical industrial test objects, specifically chosen as candidates which would be expected to be too dense for relatively low-voltage medical scanners. The respective test objects were scanned with both medical and microCT scanners and the results compared for the purpose of industrial non-destructive analysis. The test objects are a steel turbine blade, a titanium casting, a concrete cylinder with aggregate stones and porosity, and a concrete block with metal fiber reinforcement.

References

14