Control of Humidity in Small Controlled-environment Chambers using Glycerol-Water Solutions

Charles F. Forney, David G. Brandl

HortTechnology · 1992 · 142 citations · 5 references

DOIFull text

Open access

Concepts

Abstract

Solutions of glycerol and water provide a convenient and inexpensive system to control the relative humidity (RH) in small controlled-environment chambers. The relationship between the specific gravity (SG) of a glycerol-water solution and its equilibrium RH is described by the equation SG = [-0.189 (RH) + 19.9] 0.0806 . Gas can be humidified by bubbling it through jars containing solutions of glycerol-water with the desired equilibrium RH. The effects of flow rate, volume of solution, temperature, and pressure on the equilibrium RH are discussed.

References

5