MedicineNeurosurgerySurgeryInterventional RadiologyMedical RoboticsMicrosurgeryInterventional RoboticsRobot-assisted SurgeryStereotactic NeurosurgeryStereotactic SurgerySurgical RoboticsAccuracyBiopsy Needle PlacementRobotic Biopsy GuidanceRobotic Biopsy SystemsRobotic NeurosurgeryStereotactic Needle BiopsyStereotactic Needle PlacementStereotactic Tumor Biopsy
OBJECTIVE Robotic devices have recently been introduced in stereotactic neurosurgery in order to overcome the limitations of frame-based and frameless techniques in terms of accuracy and safety. The aim of this study is to evaluate the feasibility and accuracy of the novel, miniature, iSYS1 robotic guidance device in stereotactic neurosurgery. METHODS A preclinical phantom trial was conducted to compare the accuracy and duration of needle positioning between the robotic and manual technique in 162 cadaver biopsies. Second, 25 consecutive cases of tumor biopsies and intracranial catheter placements were performed with robotic guidance to evaluate the feasibility, accuracy, and duration of system setup and application in a clinical setting. RESULTS The preclinical phantom trial revealed a mean target error of 0.6 mm (range 0.1-0.9 mm) for robotic guidance versus 1.2 mm (range 0.1-2.6 mm) for manual positioning of the biopsy needle (p < 0.001). The mean duration was 2.6 minutes (range 1.3-5.5 minutes) with robotic guidance versus 3.7 minutes (range 2.0-10.5 minutes) with manual positioning (p < 0.001). Clinical application of the iSYS1 robotic guidance device was feasible in all but 1 case. The median real target error was 1.3 mm (range 0.2-2.6 mm) at entry and 0.9 mm (range 0.0-3.1 mm) at the target point. The median setup and instrument positioning times were 11.8 minutes (range 4.2-26.7 minutes) and 4.9 minutes (range 3.1-14.0 minutes), respectively. CONCLUSIONS According to the preclinical data, application of the iSYS1 robot can significantly improve accuracy and reduce instrument positioning time. During clinical application, the robot proved its high accuracy, short setup time, and short instrument positioning time, as well as demonstrating a short learning curve.
61
Randomized Trial of Cerebrospinal Fluid Shunt Valve Design in Pediatric Hydrocephalus
James M. Drake, John R. W. Kestle, Ruth Milner et al. · Neurosurgery · 1998 · 698 citations
Long-Term Follow-Up Data from the Shunt Design Trial
John Kestle, James M. Drake, Ruth Milner et al. · Pediatric Neurosurgery · 2000 · 419 citations
Mechanical Complications in Shunts
Christian Sainte‐Rose, Joseph H. Piatt, Dominique Rénier et al. · Pediatric Neurosurgery · 2008 · 416 citations
Medicine, Pediatrics, Surgery +13
Clinical use of a frameless stereotactic arm: results of 325 cases
John G. Golfinos, Brian C. Fitzpatrick, L Smith et al. · Journal of neurosurgery · 1995 · 372 citations
The safety and efficacy of stereotactic biopsy for intracranial lesions
Walter A. Hall · Cancer · 1998 · 347 citations · Full text
Medicine, Neurosurgery, Surgery +14