Comparison of automated erythrocytapheresis versus manual exchange transfusion to treat cerebral macrovasculopathy in sickle cell anemia

Bérengère Koehl, Julie Sommet, Laurent Holvoet, Hendy Abdoul, Priscilla Boizeau, Ghislaine Ithier, Florence Missud, Nathalie Couque, Suzanne Verlhac, Pauline Voultoury,

Transfusion · 2016 · 32 citations · 13 references

Abstract

Our study shows that continuous MET has comparable efficacy to the automated method in terms of stroke prevention, decrease in HbS, and iron overload prevention. It is feasible in all hospital settings and is often combined with AET successively over time.

References