Journal of Applied Crystallography · 2016 · 59 citations · 57 references
Natural SciencesMaterials ScienceBiomedical ImagingDiagnostic ImagingNuclear InstrumentationComputed TomographyComputed Tomography PhysicsX-ray CrystallographyX-ray Data AnalysisX-ray DiffractionX-ray OpticsData Collection StrategyDiffraction Data CollectionFixed-bed Reactor DesignIn Situ X-ray DiffractionResolutionsSpatial Resolution AnalysisSpatial Resolution MeasurementX-ray Computed Tomography
Interlaced scanning can be applied to various pencil‑beam tomographic techniques, including X‑ray fluorescence, absorption fine structure, pair distribution function, and scanning transmission X‑ray microscopy. The study discusses how the data‑collection strategy can be further improved to allow post‑collection tuning of statistical, temporal, and spatial resolutions. The authors present a data‑collection strategy that permits post‑experiment selection of temporal or spatial resolution, enabling rapid time‑resolved studies or higher spatial detail, and demonstrate its use on an Mn–Na–W/SiO₂ fixed‑bed reactor in situ.
An X-ray diffraction computed tomography data-collection strategy that allows, post experiment, a choice between temporal and spatial resolution is reported. This strategy enables time-resolved studies on comparatively short timescales, or alternatively allows for improved spatial resolution if the system under study, or components within it, appear to be unchanging. The application of the method for studying an Mn–Na–W/SiO 2 fixed-bed reactor in situ is demonstrated. Additionally, the opportunities to improve the data-collection strategy further, enabling post-collection tuning between statistical, temporal and spatial resolutions, are discussed. In principle, the interlaced scanning approach can also be applied to other pencil-beam tomographic techniques, like X-ray fluorescence computed tomography, X-ray absorption fine structure computed tomography, pair distribution function computed tomography and tomographic scanning transmission X-ray microscopy.
57
The Activated Complex in Chemical Reactions
Henry Eyring · The Journal of Chemical Physics · 1935 · 5.7K citations