Review of Scientific Instruments · 2016 · 20 citations · 22 references
Heater Temperature TransientsElectrical EngineeringHeat Transfer ProcessHigh Temperature MaterialsEngineeringPhase-change MaterialThermal ManagementThermal AnalysisThermal ModelingThermodynamicsHeat TransferInstrumentationMicroelectronicsThermal EngineeringTime Domain TransmissometryPhase Change SwitchesRefrigeration
A high temperature high-speed tungsten micro heater was fabricated and tested for application in phase change switches to indirectly heat and transform phase change material. Time domain transmissometry was used to measure heater temperature transients for given electrical inputs. Finite element modeling results on heater temperature transients show a good consistency between experiments and simulations with 0.2% mismatch in the best case and 13.1% in the worst case. The heater described in this work can reliably reach 1664 K at a rate of 1.67 × 10(10) K/s and quench to room temperature with a thermal RC time constant (time for T to fall by a factor of e) of less than 40 ns.
22
Nanosecond switching in GeTe phase change memory cells
Gunnar Bruns, P. Merkelbach, Carl Schlockermann et al. · Applied Physics Letters · 2009 · 450 citations
Reset State, Electrical Engineering, Non-volatile Memory +12