PLoS ONE · 2015 · 45 citations · 28 references
Life SciencesGeneticsMolecular GeneticsGenomicsMedical GeneticsPrenatal DiagnosisDna SequencingGenome SequencingNext-generation SequencingNoninvasive Prenatal TestingPrenatal Genetic DiagnosisPrenatal Molecular TestingNext-generation Sequencing Assay ValidationNext-generation Sequencing AssaysNext-generation Sequencing-based DiagnosisPrenatal Chromosomal DiagnosisPrenatal Detection Of Copy Number VariantsPrenatal GenomicsPrenatal Whole-genome SequencingTrisomy Screening
OBJECTIVES: The aims of this study were to test the utility of benchtop NGS platforms for NIPT for trisomy 21 using previously published z score calculation methods and to optimize the sample preparation and data analysis with use of in silico and physical size selection methods. METHODS: Samples from 130 pregnant women were analyzed by whole genome sequencing on benchtop NGS systems Ion Torrent PGM and MiSeq. The targeted yield of 3 million raw reads on each platform was used for z score calculation. The impact of in silico and physical size selection on analytical performance of the test was studied. RESULTS: Using a z score value of 3 as the cut-off, 98.11%-100% (104-106/106) specificity and 100% (24/24) sensitivity and 99.06%-100% (105-106/106) specificity and 100% (24/24) sensitivity were observed for Ion Torrent PGM and MiSeq, respectively. After in silico based size selection both platforms reached 100% specificity and sensitivity. Following the physical size selection z scores of tested trisomic samples increased significantly--p = 0.0141 and p = 0.025 for Ion Torrent PGM and MiSeq, respectively. CONCLUSIONS: Noninvasive prenatal testing for chromosome 21 trisomy with the utilization of benchtop NGS systems led to results equivalent to previously published studies performed on high-to-ultrahigh throughput NGS systems. The in silico size selection led to higher specificity of the test. Physical size selection performed on isolated DNA led to significant increase in z scores. The observed results could represent a basis for increasing of cost effectiveness of the test and thus help with its penetration worldwide.
28
Trimmomatic: a flexible trimmer for Illumina sequence data
Anthony Bolger, Marc Lohse, Björn Usadel · Bioinformatics · 2014 · 69.7K citations · Full text
Fast gapped-read alignment with Bowtie 2
Ben Langmead, Steven L. Salzberg · Nature Methods · 2012 · 61.1K citations
Presence of fetal DNA in maternal plasma and serum
Yuk Ming Dennis Lo, Noemi Corbetta, P. Chamberlain et al. · The Lancet · 1997 · 3.1K citations