MedicineNeuroscienceNuclear MedicineBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyBrain ImagingImage QuantificationImage ReconstructionMedical ImagingNeuroimaging PhysicsParkinson DiseaseAbsolute QuantificationIn Vivo ImagingMonte Carlo Scatter CorrectionRadiotracer QuantificationRadiotracer Uptake QuantificationScatter CompensationScatter Correction AlgorithmsTracer Uptake Quantification
UNLABELLED: Dopamine transporter (DAT) ligands have been developed for in vivo imaging of the dopaminergic system in SPECT. Although the visual analysis of SPECT images is, in general, suitable for clinical assessment, the accurate quantification of the striatal uptake might increase the sensitivity of the technique and help in the early diagnosis, follow-up, and eventual treatment response of Parkinson's disease (PD). This work is focused on assessment of the quantification of specific uptake of (99m)Tc-DAT ligands when compensation for all degrading phenomena is performed. METHODS: The SimSET Monte Carlo (MC) code was used to generate a set of SPECT projections of a numeric striatal phantom with different specific uptake ratios (SURs). An absolute quantification method (AQM), which performs a MC-based scatter compensation and a fully 3-dimensional (3D) reconstruction, was implemented. The scatter estimate was included in the reconstruction algorithm. RESULTS: The use of attenuation, point-spread-function (PSF), and scatter corrections resulted in an improvement in the value of the SUR of 37% on average with respect to the reconstruction without corrections. The magnitude of each improvement corresponded to 7% for the attenuation correction, 12% for the PSF correction using a 2-dimensional reconstruction algorithm and a further 11% for the PSF correction using a 3D reconstruction algorithm, and 7% for the scatter correction. CONCLUSION: Our findings indicate that the PSF correction plays a major role in the quantification of striatal uptake in comparison with the attenuation correction and the scatter correction. The implemented method also provides an absolute quantification procedure based on MC methods that do not depend on empiric approximations. The relative quantification results using the proposed AQM accounted for 96%-97% of the nominal SUR, whereas the limit achieved using only primary photons attained 98%-99%. The volumetric activity values obtained using the AQM converged toward the nominal values.
27
Margaret M. Hoehn, Melvin D. Yahr · Neurology · 1967 · 12K citations · Full text
Improved SPECT quantification using compensation for scattered photons.
Jaszczak Rj, Greer Kl, Floyd Ce et al. · PubMed · 1984 · 561 citations
Jan Booij, Gerrit Tissingh, Gerard J. Boer et al. · Journal of Neurology Neurosurgery & Psychiatry · 1997 · 440 citations · Full text