IEEE Transactions on Biomedical Circuits and Systems · 2015 · 89 citations · 26 references
EngineeringBioengineeringBiomedical EngineeringBiosensorsMicroelectromechanical SystemsSensorsCell Culture MicrosystemsCell-based BiosensorsElectrochemical BiosensorsMems SensorsMicroelectrode ArraysMicroscale BiosensorsBacterial SensorsGold Electroless PlatingMicroelectrode FabricationMicrofabrication Of Electrode ArraysMicromachined SensorsMicroscale SensingSensitivitySensor Arrays
The development of two new types of high-density, electroless plated microelectrode arrays for CMOS-based high-sensitivity direct bacteria and HeLa cell counting are presented. For emerging high-sensitivity direct pathogen counting, two technical challenges must be addressed. One is the formation of a bacteria-sized microelectrode, and the other is the development of a high-sensitivity and high-speed amperometry circuit. The requirement for microelectrode formation is that the gold microelectrodes are required to be as small as the target cell. By improving a self-aligned electroless plating technique, the dimensions of the microelectrodes on a CMOS sensor chip in this work were successfully reduced to 1.2 μm × 2.05 μm. This is 1/20th of the smallest size reported in the literature. Since a bacteria-sized microelectrode has a severe limitation on the current flow, the amperometry circuit has to have a high sensitivity and high speed with low noise. In this work, a current buffer was inserted to mitigate the potential fluctuation. Three test chips were fabricated using a 0.6- μm CMOS process: two with 1.2 μm × 2.05 μm (1024 × 1024 and 4 × 4) sensor arrays and one with 6- μm square (16 × 16) sensor arrays; and the microelectrodes were formed on them using electroless plating. The uniformity among the 1024 × 1024 electrodes arranged with a pitch of 3.6 μm × 4.45 μm was optically verified. For improving sensitivity, the trenches on each microelectrode were developed and verified optically and electrochemically for the first time. Higher sensitivity can be achieved by introducing a trench structure than by using a conventional microelectrode formed by contact photolithography. Cyclic voltammetry (CV) measurements obtained using the 1.2 μm × 2.05 μm 4 × 4 and 6- μm square 16 × 16 sensor array with electroless-plated microelectrodes successfully demonstrated direct counting of the bacteria-sized microbeads and HeLa cells.
26
Biosensors for detection of pathogenic bacteria
Dmitri Ivnitski, Ihab Abdel‐Hamid, Plamen Atanasov et al. · Biosensors and Bioelectronics · 1999 · 932 citations
S. Natarajan, M. Agostinelli, Sheikh A. Akbar et al. · 2014 · 532 citations
Engineering, Computer Engineering, Electrical Engineering +16
Kate Templeton, Sitha A. Scheltinga, Matthias F. C. Beersma et al. · Journal of Clinical Microbiology · 2004 · 474 citations · Full text
Fluorescent Imaging of Single Nanoparticles and Viruses on a Smart Phone
Qingshan Wei, Hangfei Qi, Wei Luo et al. · ACS Nano · 2013 · 461 citations