IEEE Control Systems · 1997 · 651 citations · 12 references
EngineeringMechanical EngineeringMechatronics EngineeringActuatorsMechatronicsMicroelectromechanical SystemsActuation SystemsActuator ControlActuator DesignActuator ModelingPiezoelectric ActuationPiezoelectric ActuatorsActuator Hysteresis ModelingCausal RepresentationElectromechanical ModelingHysteresisMicroelectromechanical ActuatorsMicromanipulationPiezoelectric Actuator ModelingStack Actuators
A nonlinear lumped-parameter model of a piezoelectric stack actuator has been developed to describe actuator behavior for purposes of control system analysis and design, and, in particular, for microrobotic applications requiring accurate position and/or force control. In formulating this model, the authors propose a generalized Maxwell resistive capacitor as a lumped-parameter causal representation of rate-independent hysteresis. Model formulation is validated by comparing results of numerical simulations to experimental data. Validation is followed by a discussion of model implications for purposes of actuator control.
12
Impedance Control: An Approach to Manipulation
Neville Hogan · 1984 · 2.9K citations
Engineering, Mechanical Engineering, Robotics Engineering +16
Forced vibrations of mechanical systems with hysteresis
R. Bouc · Medical Entomology and Zoology · 1967 · 611 citations