Determination of moisture content in mass impregnated cable insulation using low frequency dielectric spectroscopy

R. Neimanis, Tapan Kumar Saha, R. Eriksson

2002 · 46 citations · 4 references

Concepts

Abstract

The variations in the low frequency dielectric spectra of mass impregnated insulation depending on its moisture content have been investigated. For the calibration purposes a number of the impregnated paper samples was kept in the desiccators where different relative humidities were maintained. Thus obtained moisture content in the samples ranged from 1% up to 6%. The variations of the complex capacitance in a frequency range of 0.001-1000 Hz were measured on these samples as well as on paper previously dried at elevated temperatures under vacuum. The moisture content of the dried samples determined was in a range 0.2-0.5%. Moreover the study of water penetration in a 12 kV mass impregnated cable sample was carried out. Continuous measurements of the dielectric spectra revealed the dynamics of water ingress in the cable insulation.

References

4