Measurement Science and Technology · 2014 · 69 citations · 18 references
EngineeringEducational MeasurementGeodesyMachine VisionMetrologyAngle MeasurementAngular MeasurementCalibrationEquipment CalibrationSensor CalibrationSpatial CalibrationAngular Measurement SystemsEncoder Error CorrectionEncodersExperimental Data CollectionReference StandardsSelf-calibrationSensor Self-calibrationUncertainty Budget
At the Physikalisch-Technische Bundesanstalt (PTB), a self-calibration method for the fast and precise in situ calibration of angle encoders without recourse to external reference standards has been developed. It relies on a suitable geometric arrangement of multiple reading heads which read out the radial grating of the angle encoder at different angular positions. Fourier-based algorithms are used to analyse the measurement differences of pairs of heads to recover the graduation error of the grating. A comprehensive overview, both theoretical and experimental, of the capabilities and limitations of the self-calibration method is presented, including experimental data obtained with the high-precision primary angle standard of PTB. The evaluation and, where it is possible, correction of error influences due to lateral shifts of the centre of the encoder's grating during its rotation, including its eccentricity, the reading heads' angular positions, and their non-uniform response, are discussed in detail, as well as the resulting uncertainty budget.
18
R. Probst, Reiner Wittekopf, Michael Krause et al. · Measurement Science and Technology · 1998 · 116 citations
Solution to the shearing problem
Clemens Elster, I. Weingärtner · Applied Optics · 1999 · 108 citations
Natural Sciences, Biomedical Engineering, Biomedical Optics +10