Evaluation of a Macrofoam Swab Protocol for the Recovery of <i>Bacillus anthracis</i> Spores from a Steel Surface

66

Citations

11

References

2006

Year

Abstract

A protocol to recover Bacillus anthracis spores from a steel surface using macrofoam swabs was evaluated for its accuracy, precision, reproducibility, and limit of detection. Macrofoam swabs recovered 31.7 to 49.1% of spores from 10-cm2 steel surfaces with a < or =32.7% coefficient of variation in sampling precision and reproducibility for inocula of > or =38 spores.