Applied and Environmental Microbiology · 2005 · 400 citations · 52 references
Life SciencesInfectious DiseasesMicrobiologyMedical MicrobiologyMolecular VirologyVirologyEnvironmental VirologyInfectious DiarrheaViral InfectionsWater QualityInfectious Risk AssessmentNorovirus DetectionSewage ContaminantsSewage-associated VirusesViral Contamination Of Drinking WaterViral Contamination Of Surface WatersViral Contamination Of WaterWaterborne Viruses
Virus concentrations in source waters are typically below detection limits in drinking water, so assessing infectious risk requires measuring virus levels in source waters and evaluating treatment removal efficiency. Noroviruses were detected at 4–4,900 PCR‑detectable units per liter in river water, higher than in treated sewage and comparable to raw sewage, with human GII.4 Lordsdale predominating, while rotaviruses and other enteric viruses were also present at lower levels, suggesting a substantial infectious disease burden from urban sewage contamination.
ABSTRACT Since virus concentrations in drinking waters are generally below the detection limit, the infectious risk from drinking water consumption requires assessment from the virus concentrations in source waters and removal efficiency of treatment processes. In this study, we estimated from reverse transcription-PCR on 10-fold serially diluted RNA that noroviruses, the most prevalent waterborne gastroenteritis agents, were present at 4 (0.2 to 38) to 4,900 (303 to 4.6 × 10 4 ) PCR-detectable units (PDU) per liter of river water (ranges are given in parentheses). These virus concentrations are still high compared with 896 to 7,499 PDU/liter of treated sewage and 5,111 to 850,000 PDU/liter in raw sewage. Sequencing analyses designated human norovirus GGII.4 Lordsdale as the most prevalent strain in the sampling period 1998 to 1999 in both sewage and surface waters. Other GGII strains were also very abundant, indicating that the majority of the virus contamination was derived from urban sewage, although very divergent strains and one animal strain were also detected in the surface and sewage waters. Rotaviruses were also detected in two large rivers (the Maas and the Waal) at 57 to 5,386 PDU/liter. The high virus concentrations determined by PCR may in part be explained by the detection of virus RNA instead of infectious particles. Indeed, reoviruses and enteroviruses that can be cultured were present at much lower levels, of 0.3 to 1 and 2 to 10 PFU/liter, respectively. Assuming 1% of the noroviruses and rotaviruses to be infectious, a much higher disease burden than for other viruses can be expected, not only because of the higher levels but also because of these viruses' higher infectivity and attack rates.
52
Rapid and simple method for purification of nucleic acids
René Boom, C. J. A. Sol, M M Salimans et al. · Journal of Clinical Microbiology · 1990 · 5.3K citations · Full text
An Introduction to the Theory of Statistics
Human susceptibility and resistance to Norwalk virus infection
Lisa C. Lindesmith, Christine L. Moe, Séverine Marionneau‐Lambot et al. · Nature Medicine · 2003 · 1.1K citations
STAT1-Dependent Innate Immunity to a Norwalk-Like Virus
Stephanie M. Karst, Christiane E. Wobus, Margarita K. Lay et al. · Science · 2003 · 832 citations
Laboratory efforts to cultivate noroviruses
Erwin Duizer, Kellogg J. Schwab, Frederick H. Neill et al. · Journal of General Virology · 2004 · 594 citations